SINTERIT POWDER HANDLING STATION User Manual page 33

Table of Contents

Advertisement

Image 45. Attach the flange of the sieve
to the magnetic holders.
6.
Pull out the Sifting module
7.
Remove the Antistatic hose from the connector for the Antistatic hose in PHS
Image 47. Pull out both drawers with the Sifting module.
8.
Connect a PVC brush to the pulled end of the Antistatic
hose.
9.
Check that the grounding of your ATEX Vacuum
Cleaner is properly installed.
10. Turn on the vacuum cleaner and clean the sieve
(image 49) and the sieve drawer. Treat the contents of
the vacuum cleaner as waste for disposal.
11. When you have finished vacuuming, turn off the
vacuum cleaner and remove the PVC brush from the
Antistatic hose.
12. Connect the Antistatic hose back to the connector for
the Antistatic hose in the PHS
11
- both drawers
31
and
31
37
12
(image 50).
31
32
37
38
Image 46. Unlock the locks of drawers:
the sieve and the Metal container.
37
at the same time (image 47).
12
Image 48. Remove the Antistatic hose
from the PHS connector for the Antistatic hose.
30
30
Image 49. Clean the sieve from residual powder.
Image 50. Insert the Antistatic hose into the PHS.
(image 48).
POWDER HANDLING STATION Manual | 32