B. STEP TWO - MIXING OF POWDER (HOMOGENISATION)
To ensure that both types of powders mix thoroughly (both in the first and second method), we recommend sieving them
2-3 times to obtain a homogeneous blend.
1.
Take out from Drawer 3 and place the Funnel on the Metal container. Remember to put a clamping ring between the
Funnel and the Metal Container.
2.
Turn on the vacuum cleaner (from „0" to „1"). Vacuum Suction sensor indicator
3.
Press the ON/OFF Sifting button
4.
On the Control panel, in the SUCTION section, the LED above the DEPOWDERING ZONE
5.
Gently pour the entire content of the Metal container onto the Powder Chamber grid
powder on the grid of the Fine Dust Chamber
6.
After emptying the Powder Chamber and sifting the powder, remove the Metal container from the Sifting module
and put a new one in its place.
7.
To ensure homogeneous mixing of the powders, repeat steps 1-6 at least once more.
8.
The newly created powder (Print Ready Powder) is mixed and ready to use in the Sinterit Lisa/Lisa PRO printer.
PRE-
PRINT
READY
POWDER
1. CONNECT METAL CONTAINER
WITH POWDER TO THE FUNNEL
Image. 42. Process of mixing of both powders (Pre-Print Ready) - powder homogenization.
14
to turn on the Sifting Module
2
- there must be access to the air!
22
should light up.
11
and the Powder Feeding Screw
1
. Remember not to pour the
2. POUR THE POWDER INTO CHAMBER
TO MIX IT BY THE PHS SYSTEM
POWDER HANDLING STATION Manual | 30
23
.
17
should be activated.
PRINT
READY
POWDER