ATTO Technology iPBridge 2600 Installation And Operation Manual page 53

Atto technology ipbridge 2600 bridges: user guide
Hide thumbs Also See for iPBridge 2600:
Table of Contents

Advertisement

SCSIPortReset
Resets the specified SCSI bus.
SCSIPortReset [sb]
SNTP
Controls the SNTP (Simple Network Time Protocol)
settings for the iPBridge. When enabled, the iPBridge
tries to contact a specified SNTP server at reset and every
12 hours after to initialize/synchronize the time.
Default: Enabled
set SNTP [enabled|disabled]
Requires a SaveConfiguration command
get SNTP
SNTPServer
Controls the IP address of the SNTP time server that the
iPBridge contacts to initialize/synchronize the time.
If the iPBridge is unable to contact the specified SNTP
server within 30 seconds, the iPBridge tries to contact the
first auxiliary SNTP time server. If the first auxiliary
SNTP time server is not available, the iPBridge tries to
contact the second auxiliary SNTP time server. If the
second auxiliary SNTP time server is not available, the
iPBridge continues to approximate the time based on the
most recent SNTP time server, physical real time clock or
manual initialization/synchronization.
Alternative auxiliary time servers
129.6.15.28 (www.time-a.nist.gov)
132.163.4.101 (www.time-a-timefreq.bidrdoc.gov)
Default: 192.43.244.18 (www.time.nist.gov)
set SNTPServer [xxx.xxx.xxx.xxx]
Requires a SaveConfiguration command
get SNTPServer
SpeedWrite
When enabled, improves the performance of FCP WRITE
commands to SCSI devices attached to the iPBridge.
Specify SCSI bus (sb), target (st), LUN (sl) of a mapped
SCSI device or (all) for each currently mapped device.
set SpeedWrite scsi [sb st sl | all] [enabled | disabled]
get SpeedWrite scsi [sb st sl | all ]
SpeedWriteDefault
When enabled, SpeedWrite performance enhancement is
set as the default for any subsequent SCSI devices
mapped manually or via an AutoMap operation. If
disabled, the iPBridge does not attempt SpeedWrite
performance enhancement to newly-mapped SCSI
devices.
set SpeedWriteDefault [enabled | disabled]
get SpeedWriteDefault
Time
Controls the time for the iPBridge if SNTP has been
disabled or is not available.
set Time [HH]: [MM]: [SS]
Requires a SaveConfiguration command
get Time
TimeZone
Controls the time zone for the iPBridge if SNTP has been
disabled or is not available. Choices are EST, CST,
MST,
PST or numerical offset from GMT in the form of
.
+/-:HH:MM.When SNTP is enabled, the iPBridge
applies the time zone setting to the time retrieved from a
specified SNTP time server to determine local time.
Default: EST
set TimeZone [ [EST | CST | MST | PST] [+ / - HH :MM ] ]
Requires a SaveConfiguration command
get TimeZone
Username
Specifies user name for all TCP/IP, FTP and
ExpressNAV web server sessions.The user name is case
insensitive, 1-32 characters, no spaces. Changes to the
Admin Level Username requires an Admin Level
password.
Default: root
set Username
Requires a SaveConfiguration command
get Username
44
Interfaces: CLI

Advertisement

Table of Contents
loading

Table of Contents