ATTO iPBridge diagnostic commands help validate iPBridge operation and diagnose/isolate iPBridge
faults. Event logging is a mechanism for on-site observation of internal iPBridge behavior such as
tracing commands received over the GbE from the host and return of data and status to the host.
BridgeModel
Reports model information about a specific iPBridge
get BridgeModel
BridgeName
Specifies name used to identify individual iPBridge units.
May be up to a maximum of eight characters. It is not the
World Wide Name (WWN).
set BridgeName [value]
Requires a SaveConfiguration command
get BridgeName
ClearEventLog
Clears the contents of the event log. No events are
recorded until the command has been completed.
ClearEventLog
ClearTraceLog
Clears the contents of the trace log. No events are
recorded until the command has been completed.
ClearTraceLog
DisplayEventLog
Displays the most recent page of event log entries. Typing
a +, - or = causes the next, previous or same page of event
log entries to be displayed. No events are recorded until
the command has been completed. Type <escape> to
disable the command, begin new log entries, and return
to CLI.
DisplayEventLog < + | - | =| ESC>
39
ATTO Technology Inc. iPBridge Installation and Operation Manual
7.1.3 Diagnostic commands
DisplayEventLogFilter
Filters the display of data using the DumpEventLog
command for specific iPBridge subsystems when in
DisplayEventLog mode. If enabled for a particular
subsystem and level, that subsystem and level are masked
when the command DisplayEventLog is issued.
Subsystem entries:
FC
ENET
NVRAM
PERF
ECC
ALL
GEN
HTTP
iSCSI
Default: disabled
set DisplayEventLogFilter [subsystem] [level]
get DisplayEventLogFilter [subsystem] [level]
DisplayTraceLog
Displays the most recent page of trace log entries. Typing
a +, - or = causes the next, previous or same page of trace
log entries to be displayed. No events are recorded until
the command has been completed. Type <escape> to
disable the command, begin new log entries, and return
to CLI.
DisplayTraceLog < + | - | = | ESC>
DisplayTraceLogFilter
Filters the display of data using the DumpTraceLog
command for specific ports when in DisplayTraceLog
mode. If all is set for a particular port, all information
about that port are captured when the command
DisplayTraceLog is issued. If disabled is set for a port,
no trace log entries for the port are displayed.
Default: all all all
set DisplayTraceLogFilter [scsi| all] [sb | all] [chkcond | all]
get DisplayTraceLogFilter [scsi | all] [sb | all]
Log level entries:
INFO
WARN
CRIT
FAIL
ALL

Advertisement

Table of Contents
loading

Table of Contents