7 Data Path and LED Control..................31 LED Control for Internal SAS Connectors 8 Troubleshooting......................40 Appendix A Glossry......................i Appendix B VMware Configuration & Management............iii Driver Configuration Adapter Management Appendix C Standards and Compliances..............vi Appendix D Safety and Warranty.................vii Safety ATTO Technology, Inc. limited warranty...
1 ATTO Provides Storage Solutions ATTO Technology ExpressSAS low-profile HBAs and RAID adapters provide 6Gb and 12Gb SAS/SATA connectivity for IT and digital video environments. The ATTO ExpressSAS adapter family provides CAUTION CAUTION enhanced reliability and performance thanks to more Back up your system data before changing than 25 years of ATTO experience.
Page 6
H120F technical specifications H1244 technical specifications • 16 internal SFF-8643 SAS ports to PCIe 3.0 host • 4 external SFF-8644, 4 internal SFF-8643 SAS interface ports to PCIe 3.0 host interface • Up to 12Gb/s per port performance • Up to 12Gb/s per port performance •...
ExpressSAS 6Gb Host HBAs H680 technical specifications ATTO ExpressSAS Host HBAs are engineered for the most stringent IT server and digital media workgroup • Eight external SFF-8088 ports environments and are compatible with multiple • Up to 6-Gb/sec per port performance operating systems, applications, and drives.
ExpressSAS 6Gb RAID Adapters R680 technical specifications ATTO ExpressSAS RAID adapters are ideal for both IT and digital video environments that require a high level • Eight external SFF-8088 ports of protection and performance, supporting up to 256 • Up to 6-Gb/sec per port performance end devices.
Follow the on-screen instructions to complete the installation. the driver installation. Continue on to Install Hardware on page 17. Continue on to Install Hardware on page 17. 9 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual...
OS X (ExpressSAS H6xx and R6xx only) Power on your system. Follow the on-screen instructions. Double-click the downloaded driver file to Continue on to Install Hardware on page 17. launch the installer Launch Linux filename appears as Note lnx_drv_esashba#_XXX.tgz where # is the Newer PCs may ship with UEFI firmware product family and XXX is the driver’s with Secure Boot enabled.
Write the .iso image to a CD-ROM. configuring and managing ExpressSAS Use the CD-ROM as a Boot CD or an Update adapters in VMware 11 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual...
3 New Windows OS Installation When you install a new or different copy of the Windows operating system on a disk attached to an ATTO ExpressSAS adapter, you must reinstall the ATTO ExpressSAS drivers. If you are changing the version of Windows you are At the prompt, enter exit to return to the EFI using or installing a fresh copy of your current version boot manager or reset to restart the system.
If the ExpressSAS installation procedure. adapter is not in the Select the driver to be installed, click Browse and locate the driver. 13 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual...
Page 17
4 New OS X Installation Boot support is available on Intel-based systems only Adjusting Adapter settings with the EFI OS X Driver Installation Configuration Utility Note Note If you already have one or more supported products installed and you are installing Depending on your configuration, it may be additional products, you do NOT need to necessary to adjust adapter NVRAM...
Page 18
The options are as follows: -e [mask] Specify the hexadecimal event mask for event logging, defaults to 0x00000001. See the Driver Events section for more details. 15 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual...
Page 19
Driver Events number.In general, only errors that are output for event type 'Fatal' are significant; all others are mostly The reporting of driver events is controlled by the event mask driver setting. See the Driver Settings for informational or diagnostic purposes. When section for information on how to set this mask.
5 Install Hardware Use this chapter as a guide to install the ATTO ExpressSAS adapter into a x8 or x16 PCI Express expansion slot on your computer. If you have followed the Getting Started Guide successfully, you do not need to read this chapter.
Page 21
• Windows detects your adapter and automatically installs the required drivers. If drivers do not load, refer to page 9 for driver installation and troubleshooting. Turn off power to the computer. 18 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual...
Installing CacheAssure (ExpressSAS R6xx only) Adding CacheAssure to your adapter (marked ‘A’ in Exhibit 5-1) requires the installation of two modules; Non- Volatile Memory Card (B) and Power Module (C). Exhibit 5-1 ESAS RAID adapter with CacheAssure WARNING ATTO CacheAssure modules and adapters contain components that are sensitive to electrostatic discharge (ESD).
It may be live with power. If the board is mishandled while it is Exhibit 5-3 Applying mount adhesive attached it may become shorted and/or damaged. 20 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual...
7 Data Path and LED Control This chapter provides the instructions that define the internal cable connections for data path and LED control, needed for hard drive backplanes. This section applies to the following models: R608; R60F; H608; and H60F. These adapters have been designed to affect LED Control functionality through an SGPIO interface or an I2C interface.
Connecting an internal Mini-SAS to SATA backplane to determine the relationship from the SATA connector to drive slot. Fan-out cables A mini-SAS to SATA fan out cable has a mini-SAS Connecting an internal Mini-SAS to connector (SFF-8087) on one end and four SATA internal Mini-SAS cables connectors on the other end.
Page 40
Exhibit 7-5 SES-I2C Wire chart for R608 or R60F (Examples start on page 37) Mini-SAS I2C Header PHYs Backplane Backplane Connector Slots Address H608 - 2 x4 Backplanes (See example 4.) H608 - 1 x6 Backplane H608 - 1 x8 Backplane H60F –...
Page 41
Example 2 R608 with 2 Intel x4 backplanes. The backplanes are controlled by SGPIO Example 3 R60F with an Intel x6 backplane and an Intel x4 backplane. The backplanes are controlled by SES-I2C 38 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual...
Page 42
Example 4 H608 with 2 Intel x4 backplanes. The backplanes are controlled by SES-I2C Example 5 H60F with an Intel x6 backplane and an Intel x4 backplane. The backplanes are controlled by SES-I2C...
8 Troubleshooting This chapter contains solutions for the most common problems you might encounter. If you need additional assistance, please refer to the ATTO Technology website (www.attotech.com) or contact an ATTO Technology authorized representative. General suggestions a. Remove power from the PC.
Appendix A Glossary Glossary Some terms used in the SAS/SATA industry are defined below. More information is available through the ATTO Technology website ( ), or the Storage Area Networking Industry Association www.attotech.com www.snia.org Term Definition ANSI American National Standards Institute...
Page 45
Connector on Mini-SAS cables used to carry an SGPIO signal Connector Transfer Rate The rate at which bytes or bits are transferred, as in megabytes or gigabits per second ii ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual...
Appendix B VMware Configuration & Management Driver Configuration Use the esxcfg-module command to query and Configuration changes made with the esxcfg-module - configure the ATTO adapter driver parameters. In the s command are persistent across system reboots. examples that follow, <driver name> should be However, the changes will not take affect until the replaced with the ATTO driver name.
Driver version 1.60b1 filesystem, under /proc/scsi/<driver name>. Flash version 09/27/2011 Firmware version 1.16.16 To view details on a specific adapter channel, run the Copyright 2001-2011 following command: http://www.attotech.com iv ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual...
Page 48
ATTO CLI Tools Driver Parameters: ------------------ ATTO provides a set of Command Line Interface (CLI) tools for managing ATTO adapters from the Service num_sas_addr=1, sgl_page_size=512, Console of an ESX/ESXi host. These tools are num_targets=256, event_log_mask=0x00000001, distributed in a compressed TAR file with the name: num_sg_lists=1024, cmd_per_lun=7, vmw_app_hbacli_{date}.tgz.
The ATTO ExpressSAS adapters comply with Directive 2011/65/EU on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS). Contact your ATTO representative regarding RoHS compliant products. vi ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual...
ATTO Technology, Inc. limited warranty ATTO Technology, Inc. (“ATTO”) warrants to the original purchaser of this product (“Product”) that the Product is free from defects in material and workmanship for the term described for this specific Product on ATTO's website (www.attotech.com).
Page 51
ATTO DEALER, AGENT OR EMPLOYEE IS AUTHORIZED TO MAKE ANY MODIFICATION, EXTENSION OR ADDITION TO THIS WARRANTY. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. viii ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual...
Need help?
Do you have a question about the ExpressSAS H1208 HBA and is the answer not in the manual?
Questions and answers