Cli Command Explanations - ATTO Technology FastStream SC 5500E Installation And Operation Manual

Fibre channel to sas/sata embedded storage controller
Hide thumbs Also See for FastStream SC 5500E:
Table of Contents

Advertisement

Command
Username
VerboseMode
VirtualDriveInfo
WrapEventLog
zModem

CLI command explanations

Command Line Interface commands are listed alphabetically with explanations of what they are used for, their
defaults and syntax.
CAUTION
CAUTION
Using CLI without contacting an ATTO
technician is not recommended because
changing parameters may cause loss of
data and/or disruption to performance and
reliability of the FastStream.
The ExpressNAV Storage Manager is the
preferred method to manage the
FastStream. Refer to
page 41 for details.
AutoMap
Automatically assigns a subset of source protocol LUNs to a
subset of target destination devices visible to the unit. The unit
reports a five-second delay while it scans for devices. All
previous maps are deleted.
If
FCMultiNode
is enabled (multiple node):
AutoMap <fp>
SaveConfiguration command required
If
FCMultiNode
is disabled (single node): AutoMap
SaveConfiguration command required
AutoResume
Regulates the AutoResume features for interrupted rebuild
and erase operations at startup. If no group name is specified,
all existing RAID groups are affected.
Default: enabled for AutoResume Rebuild, Initialize
disabled for AutoResumeErase
set AutoResume [Rebuild | Erase |Initialize | All ] [enabled
| disabled] <group name>
BlockDevClean
Removes any RAID configuration data from the block device
with the specified block ID.
vi
ATTO Technology Inc. FastStream SC Installation and Operation Manual
Default
root
enabled
enabled
Interface Options
on
Example
set username Barbara
set verbosemode disabled
virtualdriveinfo
set wrapeventlog disabled
zmodem receive
CAUTION
CAUTION
All RAID group setup information is lost
and you lose all RAID group data.
BlockDevClean [BlockDevID]
BlockDevIdentify
Lights the LED of a disk drive. Use either RAID group name and
member index, or block ID.
BlockDevIdentify <Group name> [BlockDevID | member
index]
BlockDevIDStop
Turns off the IO LED of a previously identified disk drive.
BlockDevIDStop
BlockDevScan
Lists all currently-connected physical block devices and any
potential RAID group association. Each block device listed is
assigned a unique index at the time of the scan which is used to
identify block devices for other CLI operations.
BlockDevScan
Boot Delay
Regulates the delay (in seconds) which the unit waits after
startup before allowing hosts to detect target devices. The value
0 produces no delay.
Default: 5
set BootDelay [0-255]
get BootDelay
BridgeModel
Reports specific model and firmware information.
get BridgeModel

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 7500eFaststream sc 8500e

Table of Contents