ATTO Technology FastStream SC 5500E Installation And Operation Manual page 57

Fibre channel to sas/sata embedded storage controller
Hide thumbs Also See for FastStream SC 5500E:
Table of Contents

Advertisement

FCConnMode
Specifies the connection mode the unit uses when
communicating across a Fibre Channel network.
Connection modes:
FC_AL arbitrated loop: loop
Point-to-point: ptp
auto-negotiation, loop preferred: loop-ptp
auto-negotiation, ptp preferred: ptp-loop:
Default: loop
set FCConnMode [fp| all] [loop | ptp | loop-ptp | ptp-loop]
SaveConfiguration Restart command required
get FCConnMode [fp | all]
FCDataRate
Specifies the Fibre Channel data rate at which operation will
occur. If no connection has been made, the data rate in the
command output toggles among 1Gb, 2Gb or 4Gb on hardware
capable of 4Gb per sec., and 8Gb on hardware capable of 8 Gb
per sec.
set FCDataRate [fp | all] [1Gb | 2Gb | 4Gb | 8Gb | auto]
get FCDataRate [fp | all]
FCHard
Regulates Fibre Channel hard address assignment. When
enabled, the unit tries to use its internal hard address as its
address on the Fibre Channel loop. Under soft addressing, the
unit loop address is assigned during loop initialization.
Default: disabled
set FCHard [enabled | disabled]
SaveConfiguration Restart command required
get FCHard
FCHardAddress
Specifies the value used as the FC-AL hard address. This value
represents the address that will be used if the
command is enabled. Valid Fibre Channel hard address values
is from 0 through 125.
set FCHardAddress [fp | all] [address]
get FCHardAddress [fp | all]
FCMultiNode
Determines the reported identity of Fibre Channel ports. When
enabled (multiple node mode), each port reports a separate
unique Node Name; logical units may be mapped to any port.
When disabled (single node), each port reports the same Node
Name and each logical unit map is applied to all ports.
Note
Changing the FC port reporting causes all
maps to be deleted: you must perform a
SaveConfiguration
Info
FCHard
command before creating
new maps using the
commands.
Default: disabled
set FCMultiNode [enabled | disabled]
get FCMultiNode
FCPortErrors
Displays the number of Fibre Channel errors that have occurred
since the last reboot/power-on or use of the
ResetFCPortErrors
command.
get FCPortErrors [fp | all]
FCPortList
Displays a list of available FC ports and their current status.
Valid reported status values are Up, Down, Failed,
Reserved and Disabled.
FCPortList
FCWWName
Reports the World Wide Port Name of the Fibre Channel
interface referenced. Each Fibre Channel port has an individual
and unique 8-byte Port Name.
get FCWWName [fp | all]]
FirmwareRestart
Resets and reinitializes the unit firmware. Use the forced
option to override any CLI reservations held by other sessions.
FirmwareRestart <forced>
Help
Issued with no parameters displays a list of available CLI
commands. When a CLI command name is specified, a
command usage string and command description are
displayed.
Help <Command>
HSAdd
Assigns a Block Device to the Hot Spare pool. If RAID and RAID
group name are specified, the Hot Spare is assigned only to the
specified RAID group. If no group name is specified, the Hot
Spare is a global Hot Spare and available for use by any RAID
group.
HSAdd <RAID Group Name> [BlockDevID]
HSDisplay
Lists all devices in the Hot Spare pool.
HSDisplay
HSRemove
Removes a Block Device from the Hot Spare pool.
HSRemove [BlockDevID] [all]
AutoMap
or
Route
ix

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 7500eFaststream sc 8500e