ATTO Technology FastStream SC 5500E Installation And Operation Manual page 59

Fibre channel to sas/sata embedded storage controller
Hide thumbs Also See for FastStream SC 5500E:
Table of Contents

Advertisement

PartitionDisplay
Lists all partitions available in the specified RAID group in order
of contiguousness (as opposed to index order).
PartitionDisplay [group name]
PartitionMerge
Merges the specified contiguous partitions into one partition. All'
indicates that all unmapped partitions in a new RAID group are
merged into a single Virtual Disk.
PartitionMerge [Group Name] [[[PartIdx] [2-128]] | all]
PartitionSplit
Divides the specified unmapped partition in a new RAID group
into one or more partitions. Each new partition's capacity is
equal to the capacity of all other partitions within the original
partition.
PartitionSplit [Group Name] [Partition Index] [2-128]
PartitionWriteCache
If enabled, RAID internal Write Cache performs with a higher
write rate providing a small risk of data loss after a system
failure. If disabled, RAID internal Write Cache performs at a
higher level of data integrity with lower write performance.
set PartitionWriteCache [Group Name] [PartIdx] [enabled
| disabled]
get PartitionWriteCache [Group Name] [PartIdx]
PassThroughMode
Specifies the non-disk device types which are automatically
mapped at startup. Use all to map all non-disk devices. Use
SES to map dedicated SES processor LUNs. Use non-SES to
map all non-SES devices. Use disabled to disable the pass-
through mode.
Default: disabled
set PassThroughMode [all | SES |non-SES | disabled]
get PassThroughMode
PassThroughPersistent
Stores maps for currently-attached passthrough devices to
persistent memory,
PassThroughPersistent
PassThroughRediscover
Makes any previously-deleted pass through target devices
visible to the host.
PassThroughRediscover
Password
Specifies the password used for all sessions: Telnet, FTP and
ExpressNAV. Password is case sensitive, from 0 through 32
characters, and cannot contain spaces. Configure an empty
password by pressing Enter when asked to designate a new
password and confirmation.
Default: Password
set Password
Performance
Lists performance data for the specified Fibre Channel port
including the average rate (MB/sec.) and number of I/Os
measured over the previous sampling period. Samples are
taken about every second Successful SCSI Read (08h, 28h)
and Write (0Ah, 2Ah) commands are considered I/Os.
get Performance <fp>
Ping
Sends an ICMP echo request to the specified host.
ping [mp1] [xxx.xxx.xxx.xxx] <count <size>>
RAIDRebuildPriority
Specifies the priority a RAID rebuild has to other transactions.
Set to high to give higher priority to RAID rebuilds and lower
priority to the processing of simultaneous I/O transactions. Set
to low to give lower priority to RAID rebuilds and higher priority
to the processing of simultaneous I/O transactions. Set to same
to give equal priority to RAID rebuilds and the processing of
simultaneous I/O transactions. If a group name is specified, only
the group specified is set.
Default: same
set RAIDRebuildPriority <GroupName | all> [high | low |
same]
SaveConfiguration command required
get RAIDRebuildPriority <GroupName | all>
RAIDSpeedWriteLimit
Specifies or lists the limit on the RAID Speed Write function. Use
a lower setting with multiple initiators. A higher setting may
improve performance with multiple streams of sequential write
I/O, but too high a setting causes timeouts.
CAUTION
CAUTION
Changing the default setting may result in poor
performance or time outs.
Default: 8
set RAIDSpeedWriteLimit [0-256]
get RAIDSpeedWriteLimit
xi

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 7500eFaststream sc 8500e

Table of Contents