ATTO Technology FastStream SC 5500E Installation And Operation Manual page 63

Fibre channel to sas/sata embedded storage controller
Hide thumbs Also See for FastStream SC 5500E:
Table of Contents

Advertisement

SESDiskFailureAlarm
If enabled, activates an audible alarm on an enclosure when a
RAID member on that enclosure is detected as failed.
Default: disabled
set SESDiskFailureAlarm [enabled | disabled]
get SESDiskFailureAlarm
SESEnclosures
Lists enclosures with SES properties discovered by the unit.
SESEnclosures
SESIdentify
Commands the SES enclosure to identify the specified element.
ALL identifies all disks. RAID and RAID group name identify all
disks in a RAID group. If the Member Index is also specified,
only that disk is identified. ENC and enclosure index identify all
slots in the specified enclosure. DRIVE and BlockDevID
identify the specified disk. Use
identifying elements using ALL or ENC. If using ENC, use
BlockDevScan
first.
set SESIdentify [ALL | RAID Group Name <Member
Index> | ENC Enclosure Index | DRIVE BlockDevID]
get SESIdentify [ALL | RAID Group Name <Member
Index> | ENC Enclosure Index | DRIVE BlockDevID]
SESIdentifyStop
Commands an SES enclosure to stop identifying the specified
element. ALL stops identifying all enclosure drive slots. RAID
and RAID group name stop identifying disks in a RAID group.
ENC and enclosure index stop identifying all slots in the
enclosure. DRIVE and BlockDevID stop identifying the
specified drive. Use
SESEnclosures
elements using ALL or ENC.
SESIdentifyStop [ALL | RAID Group Name <Member
Index> | ENC Enclosure Index | DRIVE BlockDevID]
SESMute
Causes the audible alarms of all known enclosures or the
specific enclosure to be muted or set to the remind state if
supported. The remind state causes an occasional audible
reminder of the alarm condition. Use
before using this command.
Default: Mute
SESMute <Enclosure Index> <REMIND>
SESPoll
Specifies the amount of time in seconds between polling of SES
enclosures to determine their current status. Use 0 to disable
polling.
set SESPoll [0 | 30 - 3600]
get SESPoll
SESEnclosures
first before
first before identifying
SESEnclosures
first
SESStartingSlot
Establishes the starting slot/ID number for all attached SES
enclosures.
Default: 1
set SESStartingSlot [ 0 | 1]
get SESStartingSlot
SESStatus
Lists the last status of the specified element type in an
enclosure. If no element type is specified, all elements are
listed. Use
SESEnclosures
SESStatus [EnclIdx] <ENC | DRIVE | FAN | POWER |
TEMP | ALARM | SUPPORTLEVEL>
SNTP
Controls whether an SNTP time server is used to set the date
and time.
Default: enabled
set SNTP [enabled | disabled]
SaveConfiguration Restart command required
get SNTP
SNTPServer
Regulates or lists the main IP address the client uses to retrieve
the SNTP time and date.
Default: 192.43.244.18
set SNTPServer [xxx.xxx.xxx.xxx]
SaveConfiguration Restart command required
get SNTPServer
TailEventLog
Displays new events to the terminal. Type quit then press
ENTER to exit tail mode.
TailEventLog
Temperature
Lists the current internal operating temperature in degrees
Celsius. The value is read-only.
get Temperature
Time
Changes or lists the current time in 24 hour format.
set Time [HH:MM:SS]
get Time