BridgeName
Specifies an ASCII name assigned to the unit to identify
individual units. It is not the World Wide Name. Changes take
effect immediately. The name may be contain up to 8
characters.
set BridgeName [name]
SaveConfiguration Restart command required
get BridgeName
ClearEventLog
Clears the contents of the EventLog. No new entries are
recorded until the operation is completed.
ClearEventLog
Date
Regulates the current date for this unit. The date range is
1/1/2000 to 12/31/2099.
set Date [MM] / [DD] / [YYYY]
get Date
DefaultInterleave
Assigns or retrieves the system's default interleave size (in 512-
byte blocks) for new RAID groups (before
been used). If an interleave size is not explicitly specified when
a RAID group is created, then the DefaultInterleave value is
used instead.
Default: 128
set DefaultInterleave [16 | 32 | 64 | 128 | 256 | 512 | 1024
| 2048]
SaveConfiguration Restart command required
get DefaultInterleave
DeleteAllMaps
Removes all mapped devices from the map table. Upon the
subsequent POST, the default maps are loaded if no maps are
present.
DeleteAllMaps
SaveConfiguration command required
DisplayEventLog
Displays the EventLog.The event log may be filtered using the
DisplayEventLogFilter
command. The optional parameter n is
the number of lines to be displayed as a single page with no user
interaction. After the command has executed, use +, - or = to
scroll through the log. Type quit and press Enter to exit the
command.
DisplayEventLog <n>
DisplayEventLogFilter
Filters the display of data for specified subsystems and levels
during
entries are platform-dependent. For set commands, the final
parameter indicates whether or not events from the specified
subsystem and level are displayed.
Default: all all all
set DisplayEventLogFilter [subsystem | all] [level | all] [all
get DisplayEventLogFilter [subsystem |all] [level | all]
DriveTest
Starts or stops a drive test with the previously-specified
configuration and drive list. Drives which are in-use by the test
are not available for RAID configuration or RAID operations.
Only one test can be run at a time.
DriveTest [Begin | Cancel]
DriveTestConfig
Configures the next drive test to perform: initialize (destructive
write-only), read (non-destructive read-only), verify (destructive
verify), or init-verify (destructive write-read-verify).The test is not
started until the
RGCommit
has
set DriveTestConfig [init | read | verify | init-verify]
get DriveTestConfig
DriveTestList
Specifies drives to be run in the next drive test. This command
can be called with different eligible block IDs and each one is
added to the list. Drives which are not part of a RAID group or
are not hot spares are eligible. The all parameter automatically
chooses eligible drives. The test is not started until the
DriveTest
set DriveTestList [drive [BlockDevID] | all]
get DriveTestList
DriveTestStatus
Displays the status of the currently running drive test, but does
not display performance metrics. If a block device ID is not
running or cannot be found, its state is idle and percent
complete is 0.
get DriveTestStatus <drive [BlockDevID]>
DumpConfiguration
Displays the unit's configuration to the Advanced page of the
ExpressNAV Storage Manager or a terminal emulation or telnet
session. The record may not be displayed completely in the
ExpressNAV page.
DumpConfiguration
DisplayEventLog
mode. Valid event log subsystem
| none]
DriveTest
Begin command is given.
Begin command is given.