ReadOnlyPassword
Specifies a password which allows only read and no writes. It is
case sensitive, 0 to 32 characters, and cannot contain spaces.
An empty password can be configured by not specifying one.
Default: Password
set ReadOnlyPassword
ReadOnlyUsername
Specifies the user name which allows only read and no
writes. It is case insensitive, 1 to 32 characters, and
cannot contain spaces.
Default: user
set ReadOnlyUsername [username]
get ReadOnlyUsername
Reserve
Reports the state of CLI reservation for the current CLI session.
If the command reports reservations are enabled, another CLI
session has control of any changes to the unit's configuration.
Reserve
ResetFCPortErrors
Resets all Fibre Channel error counts for the specified port to
zero.
ResetFCPortErrors [fp | all]
RestoreConfiguration
Use default to force the NVRAM setting to its original defaults.
Use factory to force the NVRAM setting to its original defaults,
including the unit's World Wide Name (WWN). Use saved to
undo any changes made since the last save.
RestoreConfiguration [default | factory | saved]
RGAddStorage
Adds additional storage to an existing RAID group. Up to 10
indices of available block devices, provided by the
BlockDevScan
command, may be added to the RAID group. If
this list is omitted, use
RGMemberAdd
RGAddStorage. If you use Commit to automatically save
the configuration, all user data is removed from each new
member drive. If you do not use Commit, you must use the
command
RGCommit
to save the configuration. If you do not
use the Commit parameter and you have not used RGCommit,
you may use the command RGCancelAddStorage.
Note
MIRRORs can not be added to a RAID 4, 5 or
DVRAID group.
RGAddStorage [group name] [MIRROR | STRIPE |
SPAN] <BlockDevID>... <commit>>
xii
ATTO Technology Inc. FastStream SC Installation and Operation Manual
RGAutoRebuild
Regulates the automatic rebuild of RAID groups, first using
drives assigned as Hot Spares, then all other available drives,
as automatic replacements for any member that fails.
Default: disabled
set RGAutoRebuild [GroupName | all] [enabled |
get RGAutoRebuild [GroupName | all]
RGCancelAddStorage
Cancels the
RGCancelAddStorage [group name]
RGCommit
Saves a RAID group's configuration to its member drives. If you
add storage to an existing RAID group, the additional storage is
stamped with the existing group's configuration. Use
Advanced to initialize new drives, erasing and verifying the
drive media. The RAID group is unavailable until the operation
completes. Use Express to perform a background
initialization. The RAID group is immediately available for use.
RGCommit < Group Name <Advanced | Express> | all
RGCreate
Creates a new RAID group with the name, RAID level and
interleave level, if specified. KB denotes interleave in kilobytes.
Without the KB suffix, interleave is set in 512 byte blocks. If
interleave is not provided, the system's default interleave is
used.
RGCreate [Group Name] [RAID [0|1|10|4|5|6] |JBOD]
RGDelete
Deletes all RAID group configurations or the specified RAID
group configuration.
RGDelete [group name | all]
instead of
RGDisplay <GroupName | all>
RGDiskWriteCache
Enable Write Cache for higher write performance with a small
risk of data loss after a system failure. Disabling Write Cache
forces the drives to update the storage media at the expense of
some write performance.
set RGDiskWriteCache [Group Name | all] [enabled |
get RGDiskWriteCache [Group Name | all]
RGDisplay
Lists RAID group status information.
RGDisplay <Group Name | all>
disabled]
RGAddStorage
command.
<Advanced | Express> >
<8KB|16KB|32KB|64KB|128KB|256KB|512KB|1024
KB |16|32|64|128|256|512|1024|2048>
disabled]