ATTO Technology FastStream SC 5500E Installation And Operation Manual page 62

Fibre channel to sas/sata embedded storage controller
Hide thumbs Also See for FastStream SC 5500E:
Table of Contents

Advertisement

RGUnmap
Removes all mapped partitions of a RAID group from the routing
table. Partitions are unaffected but become inaccessible to
initiators.
RGUnmap [Group Name | all]
RGWaitTimeout
Specifies the maximum time in seconds that the system waits to
discover previously-configured RAID groupsunit. The time out is
used during system boot time and when the
command is issued.
Default: 5
set RGWaitTimeout [1-3600]
SaveConfiguration Restart command required
get RGWaitTimeout
RMStatus
Lists the status of all RAID members within a RAID group or a
specific RAID member.
RMStatus [group name] <member index>
Route
Maps a RAID partition or SAS/SATA PassThrough device onto
the Fibre Channel network as an FC LUN. Mapping a RAID
partition to a current FC LUN overwrites the previous map. If the
unit is configured for verbose mode, overwriting a map requires
secondary confirmation.
If
FCMultiNode
is enabled: Route FC [fl] [ [RAID [Group
Name] [Part Index]] | [SAS [SAS Index]]| Delete ]
If
FCMultiNode
is disabled: Route FC [fl] [ [RAID [Group
Name] [Part Index]] | [SAS [SAS Index]]| Delete ]
RouteDisplay
Lists all maps with RAID group partition identifier, group name
and FC LUN. Use Passthrough to list only Pass Through
device maps. Use Persistent to list only Pass Through maps
stored in persistent memory.
If
FCMultiNode
is enabled: RouteDisplay FC <LUN> |
<passthrough> | <persistent>
If
FCMultiNode
is disabled: RouteDisplay FC <LUN>
|<passthrough> | <persistent>
SASPortList
Lists the status of all available SAS ports.
SASPortList
SASTargets
Lists the physical devices that are connected to all SAS ports.
SASTargets
xiv
ATTO Technology Inc. FastStream SC Installation and Operation Manual
SaveConfiguration
Issued with the restart option, cycles unit power after saving
configuration changes. The norestart option saves changes
without restarting.
SaveConfiguration <Restart | NoRestart>
BlockDevScan
SerialNumber
Lists the serial number of the unit. The number is a 13-character
field. The first seven alphanumeric characters are an
abbreviation representing the product name. The remaining six
digits are the individual unit's unique number.
get SerialNumber
SerialPortBaudRate
Configures the baud rate for the unit's RS-232 serial port. The
number of data bits per character is fixed at 8 with no parity.
Default: 115200
set SerialPortBaudRate [9600 | 19200 | 38400 | 57600 |
SaveConfiguration Restart command required
get SerialPortBaudRate
SerialPortEcho
Controls if the unit echoes characters on its RS-232 port. When
enabled, all non-control character keyboard input is output to
the display.
Default: enabled
set SerialPortEcho [enabled | disabled]
get SerialPortEcho
SES
Enables support for SES enclosures that have been discovered
by the controller.
Default: enabled
set SES [enabled | disabled]
get SES
SESAlarmTest
Turns on an enclosure's audible alarm if certain conditions exist.
Reset turns off the alarm. Use
the alarm.
SESAlarmTest [Enclosure Index] [SET | RESET] [INFO |
Note
Certain modifications require a system restart.
115200]
SESEnclosures
NON-CRIT | CRIT | UNRECOV]
before setting

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 7500eFaststream sc 8500e

Table of Contents