After Creating Raid Groups - ATTO Technology FastStream SC 5500E Installation And Operation Manual

Fibre channel to sas/sata embedded storage controller
Hide thumbs Also See for FastStream SC 5500E:
Table of Contents

Advertisement

After creating RAID groups

1If you are not already in the
ExpressNAV Storage Manager,
type the IP address of your
controller in a standard browser.
On the splash screen, click
Enter Here. In the box provided,
type in your user name and
password, and click OK.
2
Click on the Diagnostics button on the left
hand side of the ExpressNAV Storage
Manager.
3
Choose Initialize and Verify Drives to test
newly added drives that are not part of a RAID
group. Choose Read-Only Drive Test to non-
destructively test any drives.
15
ATTO Technology Inc. FastStream SC Installation and Operation Manual
4
Click Next.
5
If no drives appear in the information box, click
on the System Scan button.
If drives are available, click on the drives you
wish to verify, initialize or test; the drives are
highlighted.
6
Click Commit.
CAUTION
CAUTION
Do not restart the FastStream or
disconnect or power cycle drives during
Drive Initialization and Verification or you
must start the verification process from the
beginning.
7
A warning box appears. In the warning box,
verify that you want to complete the
configuration by clicking on Yes. Clicking on No
ends the procedure without making a change.
8
The Drive Performance and Health page
appears showing what tests are running and
their results. You may select other tests to run
or continue on to other tasks.