IdentifyBridge
If you enable this command, the Fault LED on this unit blinks so
that hardware may be identified. Disabling this option cancels
the blinking..
Default: disabled
set IdentifyBridge [enabled | disabled]
get IdentifyBridge
Info
Lists version numbers and other product information for key
components. Use the optional brief to list a more concise
subset of system information.
Info <brief>
IPAddress
Controls the current IP address of the Ethernet port(s) on the
unit. If
IPDHCP
is enabled, the get command reports the
current IP address assigned by the network DHCP server,
followed by the (DHCP) identifier.
Default: 10.0.0.1
set IPAddress [mp1] [xxx.xxx.xxx.xxx]
SaveConfiguration Restart command required
get IPAddress [mp1]
IPDHCP
Regulates how the unit acquires its IP address. When disabled,
the unit uses the IP address specified by the
command; when enabled, the unit gets its IP address from a
DHCP server.
Default: enabled
set IPDHCP mp1 [enabled | disabled]
SaveConfiguration Restart command required
get IPDHCP
IPDNSServer
Controls the current DNS Server address. If
enabled, the DNS Server address is automatically detected. If
IPDHCP is disabled, you must set the address manually using
this command.
set IPDNSServer mp1 [xxx.xxx.xxx.xxx]
get IPDNSServer
IPGateway
Controls the current default gateways used by any Ethernet
port(s) on the unit. If
IPDHCP
reports the current IP gateway assigned by the network DHCP
server.
Default: 0.0.0.0
set IPGateway [mp1] [xxx.xxx.xxx.xxx]
SaveConfiguration Restart command required
get IPGateway [mp1]
x
ATTO Technology Inc. FastStream SC Installation and Operation Manual
IPAddress
CLI
IPDHCP
is
is enabled, the get command
IPSubnetMask
Controls the current subnet masks used by any Ethernet port(s)
on the unit. If
IPDHCP
is enabled, the get command reports the
current IP subnet mask assigned by the network DHCP server.
Default: 255.255.0.0
set IPSubnetMask [mp1] [xxx.xxx.xxx.xxx]
SaveConfiguration Restart command required
get IPSubnetMask [mp1]
IsReserved
Lists the reservation status of the current services session or
interface use.
IsReserved
MaxOpTemp
Regulates or lists the maximum operating temperature. Valid
entries are from 55 through 70
Default: 70
set MaxOpTemp [55 – 70]
SaveConfiguration Restart command required
get MaxOpTemp
Metrics
Controls the collection of standard data metrics within a product.
Metrics [Start | Stop | Display | Clear] [[drive [BlockDevID]
| all | running]
MinOpTemp
Regulates or lists the minimum operating temperature. Valid
entries are from 0 through 15
Default: 0
set MinOpTemp [0 – 15]
SaveConfiguration Restart command required
get MinOpTemp
OpTempWarn
Regulates or lists the offset when a warning is issued before a
thermal control event. Valid entries are from 0 to 15
degrees.
Default: 5
set OpTempWarn [0 – 15]
SaveConfiguration Restart command required
get OpTempWarn
Partition
Regulates the specified partition to the specified capacity in
gigabytes (GB), megabytes (MB), or blocks. The specified
capacity must be smaller than the specified partition's current
capacity. A new partition is created to acquire the remainder of
the original partition's space.
Partition [Group Name] [PartIdx] [capacity] [GB | MB |
blocks]
°
Celsius.
°
Celsius.
°
Celsius

Advertisement