Annunciator Model Code Definition - Ametek AN-3100D Installation And Configuration Manual

Table of Contents

Advertisement

A
NNUNCIATOR
AN-3100D-
______
Item 1
Mounting
Options
-
_____
Item 8
Operational
Sequence
Example: AN-3100D-PM-3H-6W-INTB-2-34-W-A-RR-B-X-TP-MB-TS-IB-RLY
Item 1 Mounting Options
PM
Semi-Flush Panel Mounting
PC
Semi-Flush Panel Mounting w/rear cover
RK
19" Rack Mounting (5 wide systems only)
S
Surface (Wall) Mounting (1H to 5H x 2W to 5W)
NCB
Weather-tight NEMA Front Cover w/ ¼-20 Bolts
NCT
Weather-tight NEMA Front Cover w/T Handle
N4
NEMA-4 Enclosure (1H to 6H x 3W to 8W)
N4PB
NEMA-4 Enclosure w/PB (1H to 6H x 3W to 8W)
Item 2,3 Annunciator Size
# of Cells High
(1-13)
Item 4 Common Service Cell
INTB
Integral Pushbuttons (ACK, SIL, TEST, RESET)
NPB
Pushbuttons replaced w/ a Half or Full Size Window
Note:
For either selection above, external pushbuttons
can be connected to the Annunciator terminal blocks.
Item 5 Window Size
4
Quad Size, 4 inputs per cell, ea 1.5"H x 1.5"W
3
Third Size, 3 inputs per cell, ea 1.0"H x 3.0"W
2E
Half Size, 2 inputs per cell, ea 1.5"H x 3.0"W
2S
Half Size, 2 inputs per cell, ea 1.5"H x 3.0"W
2
Half Size, 2 inputs per cell, ea 1.5"H x 3.0"W
1E
Full Size, 1 input per cell, ea 3.0"Hx3.0"W
IMW
Intermixed window size
Note:
Option 1E indicates that the cell is expandable up to 2 inputs.
Option 2E indicates that the cell is expandable up to 4 inputs.
Option 2S indicates one input module per single input provided.
Do not include the CSM Cell in your quantity.
Item 6 Active Points
Total # of active points
Item 7 Window Color
W
White Window Filter
R
Red Window Filter
A
Amber Window Filter
G
Green Window Filter
Y
Yellow Window Filter
B
Blue Window Filter
IMC
Intermix color, matrix must be included
4
M
C
D
ODEL
ODE
AN-3100D Model Number
-
-
______
_____
Item 2
Item 3
# of Cells
# of Cells
High
Wide
-
-
_____
_____
Item 9
Item 10
Repeat
Power
Relay
Input
# of Cells Wide
(2-13)
(lower right cell)
EFINITION
-
-
_____
_____
Item 4
Item 5
Common
Window
Service
Size
-
-
_____
_____
Item 11
Item 12
Field Contact Window
Voltage
Legends
Item 8 Operational Sequence
A; A4; A4-5-6; M; R; R-12 ; F1A; F2A; F3A; F2M-1;
FFAM2; F3C ; R12C ; RC
IMO
Intermixed Sequences (up to 4 available)
Item 9 Repeat Relay Option
RR
Auxiliary Repeat Relay Provided for every Input.
(Can be field configured to follow: alarm input status,
alarm sequence operation or Lamp Flash. Relays
can be set for normally energized or de-energized
operation and are jumper selectable for a Form A or
Form B contact arrangement).
FRC
Auxiliary Repeat Relay Provided for every Input with
Form C (SPDT) Contacts.
(Can only be used with Window Size 1E or 2S).
2RR
Two Repeat Relays for every input.
(Selectable for a Form A or Form B contact
arrangement. Can only be used with Window
Size 1E or 2S.)
NR
No Repeat Relays required
(Note: Can only choose one selection from above).
Item 10 Power Input
F
24 VDC
E
48 VDC
C
125 VDC
B
120 VAC, 60 HZ
A
230 VAC, 50 HZ
Item 11 Field Contact Voltage (FCV)
Field Contact Voltage internally supplied by AMETEK, with
common system-wide FCV return.
*For System Input Power Voltages of 120/230VAC or 125VDC.
D
125 VDC FCV
X
24 VDC FCV
Field Contact Voltage externally supplied by Customer, internally
bussed to all input modules.
DC
125 VDC FCV supplied by Customer
TC
48 VDC FCV supplied by Customer
XC
24 VDC FCV supplied by Customer
JC
12 VDC FCV supplied by Customer
Field Contact Voltage externally supplied by Customer.
Every input is isolated and requires a separate FCV connection.
D/ISO
125 VDC FCV supplied by Customer
T/ISO
48 VDC FCV supplied by Customer
X/ISO
24 VDC FCV supplied by Customer
J/ISO
12 VDC FCV supplied by Customer
Y/ISO
120 VAC FCV supplied by Customer
NR
No Field Contact Voltage (Serial Input Only)
AN-3100D ANNUNCIATOR INSTALLATION AND CONFIGURATION MANUAL
-
-
_____
_____
Item 6
Item 7
Active
Window
Points
Color
-
-
_____
_____
Item 13
Item 14
Comm.
Options
Options

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents