1 -
WARNINGS AND SAFETY
Our boilers are built in our plants and checked down to the
smallest detail in order to protect users and fitters from
injury. After working on the product, qualified personnel must
check the electrical wiring, in particular the stripped part of
conductors, which must not stick out from the terminal board,
avoiding possible contact with live parts of such conductor.
This instruction manual, together with the user manual, are
integral parts of the product: make sure that they are always
kept with the appliance, even if it is transferred to another
owner or user, or moved to another heating system. In case of
loss or damage, please contact your local Technical Assistance
Service for a new copy.
The boiler must only be installed and serviced by qualified
personnel, in accordance with the regulations in force.
Boiler maintenance must be carried out at least once a year.
This should be booked in advance with the Technical Assistance
Service.
The installer must instruct the user about the operation of the
appliance and essential safety requirements.
This boiler must only be used for the application it was designed
for. The manufacturer declines all contractual and non-
contractual liability for injury to persons or animals or damage
to property deriving from errors made during installation,
adjustment and maintenance and from improper use.
After removing the packaging, make sure the content is in good
condition and complete. Otherwise, contact the dealer from
whom you purchased the appliance.
The appliance's discharge manifold must be connected to a
suitable venting system. The manufacturer of the appliance is
not liable for any damage/flooding resulting from the failure of
the channel system.
Dispose of all the packaging materials in the appropriate
containers c/o specific collection centres.
Dispose of waste taking care not to harm human health and
without employing procedures or methods which may damage
the environment.
At the end of its life, the product should be not be disposed of
as solid urban waste, but rather it should be handed over to a
differentiated waste collection centre.
During installation, inform the user that:
- in the event of water leaks, the water supply must be shut
off and the Technical Assistance Service must be contacted
immediately
- regularly check that the operating pressure of the hydraulic
system is greater than 1 bar. If necessary, restore the
pressure as explained in the "System filling" section
- if the boiler has not been used for a long time, it is
recommended that the Technical Assistance Service
performs, at least, the following operations:
- turn the main switch of the appliance and the main switch
of the system to "off"
- close the fuel and water taps of the heating system
- drain the heating circuit to prevent freezing.
For safety, always remember that:
the boiler should not be used by children or unassisted disabled
people
it is dangerous to operate electrical devices or appliances
(such as switches, home appliances, etc.) if you smell gas or
combustion fumes. In the event of gas leaks, ventilate the room
opening doors and windows; close the gas general tap; request
prompt action by Technical Assistance Service professionally
qualified personnel
4
do not touch the boiler while barefoot, or if parts of your body
are wet or damp
set the function selector switch to OFF/RESET to bring up "- -"
on the display, then disconnect the boiler from the main power
supply by turning off the main system switch before carrying
out any cleaning operations
do not modify safety and adjustment devices without the
manufacturer's permission and relative instructions
do not pull, disconnect or twist the electric cables coming out
of the boiler, even when it is disconnected from the main power
supply
avoid covering or reducing the size of the ventilation openings
in the installation room
do not leave inflammable containers and substances in the
installation room
keep packaging materials out of the reach of children
it is forbidden to obstruct the condensate drainage point.
2 -
DESCRIPTION
MySMART is available in the following models:
C.S.I. are type C wall-mounted condensation boilers for heating
and the production of domestic hot water.
R.S.I. are type C wall-mounted condensation boilers capable of
operating in different conditions through a series of jumpers fitted
on the electronic board (consult the "Boiler configuration" section):
- CASE A: only heating. The boiler does not provide domestic hot
water.
- CASE B: only heating with an external thermostat-controlled
water tank: in this condition, the boiler delivers hot water to
the water tank whenever a demand is made by the relative
thermostat.
- CASE C: only heating with an external temperature probe-
controlled water tank (accessory kit available on request), for
the production of hot water. If the water tank is not supplied by
our company, make sure that the relative NTC probe has the
following characteristics: 10 kOhm at 25°C, B 3435 ±1%.
According to the flue gas outlet device, the boilers are classified
in categories B23P-B53P; C13-C13x; C33-C33x; C43-C43x;
C53,C53x; C63-C63x; C83-C83x; C93-C93x; 3CEp.
In configuration B23P (when installed indoors), the appliance cannot
be installed in bedrooms, bathrooms, showers or where there are open
fireplaces without a proper air flow. The room where the boiler is installed
must have proper ventilation. Detailed regulations for the installation of
the flue, gas piping and ventilation ducting are given in Standards UNI
7129-7131.
In configuration C, the appliance can be installed in any type of room
and there are no limitations due to ventilation conditions or room volume.
It is also possible, using a check valve included as an accessory, to
install the boiler on collective pressurised flues; for the details, see
section 3.12 "Installation on collective flues in positive pressure".
3 -
INSTALLATION
3.1
Installation regulations
Installation must be carried out by qualified personnel in compliance
with local regulations.
POSITION
MySMART is a wall-mounted boiler for heating and for the production
of hot water. There are two categories, depending on the type of
installation:
1.
B23P-B53P type boiler - forced open installation, with flue
gas discharge pipe and pick-up of combustion air from the
installation area. If the boiler is not installed outdoors, air intake
in the installation area is compulsory.