Adjustment of the domestic hot water temperature
MySMART C.S.I.
To adjust domestic water temperature (bathrooms, showers, kitchen,
etc.), turn the knob with the
marked with "+" and "-".
MySMART R.S.I.
CASE A heating only - adjustment does not apply.
CASE B heating only + external storage tank with thermostat -
adjustment does not apply.
CASE C heating only + external storage tank with probe - to adjust
the temperature of the domestic hot water in the storage tank,
turn the knob-but with the symbol
temperature and anti-clockwise to lower it.
The boiler is standby status until, after a heat request, the burner
switches on and the digital display shows the hot water system
temperature, the icon to indicate the hot water supply and the flame
icon. The boiler will be in function until the adjusted temperature is
reached, afterwards it will be in "standby" again.
If the
symbol (fig. 34) on the command panel lights up, this means
the boiler is in temporary stop status (see chapter "Faults").
The digital monitor indicates the fault code detected (fig. 34).
Automatic Ambient Adjustment System (S.A.R.A.) (fig. 35)
By setting the heating water temperature selector to the area marked
by AUTO, the S.A.R.A. self-adjusting system is activated (frequency
0.1 sec. on; - 0.1 sec. off; duration 0.5): according to the temperature
set on the ambient thermostat and the time employed to reach it, the
boiler varies automatically the heating water temperature reducing
the operating time, allowing great operation comfort and energy
saving.
4.4
Faults
BOILER STATUS
Off status(OFF)
Stand-by
ACF alarm lockout module
ACF electronics fault alarm
Limit thermostat alarm
Tacho fan alarm
Water pressure switch alarm
C.S.I.: NTC domestic water fault
R.S.I.: water tank sensor fault
NTC heating outlet fault
Heating outlet probe over-temperature
Outlet/return line probe differential alarm
NTC heating return line fault
Heating return line probe over-temperature
Outlet/return line probe differential alarm
Cleaning the primary heat exchanger
NTC flue gases fault
Flue gases probe over-temperature
Parasite flame
Low temperature system thermostat alarm
Exceeded the maximum number of RESET by remote control
(Reset possible only by boiler control panel)
Temporary pending ignition
Water pressure switch intervention
Calibration service
Calibration installer
Chimney sweep
Vent cycle
Pre-heating enabled (only C.S.I.)
Preheating heat request (only C.S.I.)
External probe presence
Domestic water heat request
Heating heat request
Antifreeze heat request
Flame present
symbol (fig. 33) within the area
clockwise to increase water
Reset function
To restore operation, set the function selector to
5-6 seconds then bring it to the required position.
When a remote control BeSMART is connected, the reset of
faults can be done also on the remote control itself, pressing
for one second the BACK/RESET
N.B. If the attempts to reset the appliance do not activate operation,
contact the Technical Assistance Centre.
4.3
Switch-off
Temporary switch-off
In the event of absence for short periods of time, set the mode
selector (fig. 36) to
(OFF). In this way (leaving the electricity
and fuel supplies enabled), the boiler is protected by the following
systems:
- Anti-frost device: when the temperature of the water in the boiler
falls below 5°C, the circulator and, if necessary, the burner are
activated at minimum output levels to bring the water temperature
back to the values for safety (35°C). During the anti-frost cycle, the
symbol
appears on the digital monitor.
- Circulator anti-blocking function: an operation cycle is activated
every 24 hours.
- DHW Antifreeze (only when connected to an external storage
tank with probe): the function is activated if the temperature
measured by the storage tank probe drops below 5° C. A heat
request is generated in this phase with the ignition of the burner at
minimum power, which is maintained until the water temperature
reaches 55° C. During the anti-frost cycle, the symbol
on the digital monitor.
Long period switching off
In case of absence for long periods of time, set the mode selector
(fig. 36) to
(OFF). Then, close the gas tap present on the system.
In this case, anti-frost device is deactivated: empty the systems, in
case of risk of frost.
DISPLAY
OFF
-
A01
A02
A03
A04
A06
A07
A08
A09
A11
A77
A99
80°C flashing
flashing
ADJ
ACO
P
P flashing
60°C
80°C
MySMART
off (fig. 36), wait
button (fig. 37).
appears
TYPES OF ALARMS
None
Signal
Definitive lockout
Definitive lockout
Definitive lockout
Definitive lockout
Signal
Temporary stop
Temporary then definitive
Definitive lockout
Temporary stop
Temporary then definitive
Definitive lockout
Signal
Temporary stop
Temporary then definitive
Temporary stop
Temporary stop
Definitive lockout
Temporary stop
Temporary stop
Signal
Signal
Signal
Signal
Signal
Signal
Signal
Signal
Signal
Signal
11

Advertisement

loading

This manual is also suitable for:

Mysmart 20 r.s.i.2010980820130770