Speed - Renishaw VIONiC REXM20 Installation Manual

Ultra-high accuracy angle encoder system
Table of Contents

Advertisement

Speed

Clocked
output
option
5 µm
1 µm
0.5 µm
0.2 µm
(MHz)
(D)
(X)
(Z)
50
12
12
12
12
12
12
40
12
12
9.06
25
20
12
12
8.06
12
12
10.36
5.18
10
12
8.53
4.27
12
6.91
3.45
08
06
12
5.37
2.69
04
12
3.63
1.81
0.730
01
4.53
0.910
0.450
0.180
*For a readhead with a 1 m cable.
Angular speed depends on ring diameter – use the following equation to convert to rev/min.
V × 1000 × 60
Angular speed (rev/min) =
π
D
VIONiC REXM20/REXT20 installation guide
Maximum speed (m/s)
0.1 µm
50 nm
40 nm
25 nm
(W)
(Y)
(H)
(M)
(P)
7.25
3.63
1.81
1.45
0.906
5.80
2.90
1.45
1.16
0.725
3.63
1.81
0.906
0.725
0.453
3.22
1.61
0.806
0.645
0.403
2.07
1.04
0.518
0.414
0.259
1.71
0.850
0.427
0.341
0.213
1.38
0.690
0.345
0.276
0.173
1.07
0.540
0.269
0.215
0.134
0.360
0.181
0.145
0.091
0.090
0.045
0.036
0.023
Where V = maximum linear speed (m/s) and
D = external diameter of REXM20/REXT20 (mm).
Minimum edge
separation* (ns)
20 nm
10 nm
5 nm
2.5 nm
(I)
(O)
(Q)
(R)
0.725
0.363
0.181
0.091
0.580
0.290
0.145
0.073
0.363
0.181
0.091
0.045
0.322
0.161
0.081
0.040
0.207
0.104
0.052
0.026
0.171
0.085
0.043
0.021
0.138
0.069
0.035
0.017
0.107
0.054
0.027
0.013
0.073
0.036
0.018
0.009
0.018
0.009
0.005
0.002
25.3
31.8
51.2
57.7
90.2
110
136
175
259
1038
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vionic rext20