Rexm20/Rext20 Installation Drawing - Renishaw VIONiC REXM20 Installation Manual

Ultra-high accuracy angle encoder system
Table of Contents

Advertisement

REXM20/REXT20 installation drawing

Dimensions and tolerances in mm
*
9.9 – 10.1
0.25
D2
D1
D3
Fiducial marks,
4 positions, to
aid installation
Section A-A
VIONiC REXM20/REXT20 installation guide
* Graduations are centred
within this dimension
NOTE: For REXT20 partial
arc please refer to
'Ring orientation for partial
arc applications', page
A
A
D-4
Nominal
Line
external
count
diameter (mm)
52*
8 192
57*
9 000
75
11 840
100
15 744
103
16 200
104
16 384
115
18 000
8.
150
23 600
183
28 800
200
31 488
206
32 400
209
32 768
229
36 000
255
40 000
300
47 200
θ
350
55 040
417
65 536
*52 mm and 57 mm rings have dimple fiducial features and no slots.
N holes Ø6
through
equispaced
Dimensions
D1
D2
D3
N
26
50
52.1 – 52.2
4
26
50
57.25 – 57.35
4
40.5
64.5
75.3 – 75.4
8
57.5
97.5
100.2 – 100.3
8
57.5
97.5
103.0 – 103.2
8
57.5
97.5
104.2 – 104.4
8
68
108
114.5 – 114.7
8
96
136
150.2 – 150.4
8
122.5
162.5
183.2 – 183.4
12
136
176
200.3 – 200.5
12
140.5
180.5
206.1 – 206.5
12
140.5
180.5
208.4 – 208.8
12
160.5
200.5
229.0 – 229.4
12
180.5
220.5
254.4 – 254.8
12
216
256
300.4 – 300.6
12
256
296
350.3 – 350.5
16
305
345
417.0 – 417.4
16
Holes
θ
D4
38
90°
38
90°
52.5
45°
77.5
45°
77.5
45°
77.5
45°
88
45°
116
45°
142.5
30°
156
30°
160.5
30°
160.5
30°
180.5
30°
200.5
30°
236
30°
276
22.5°
325
22.5°
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vionic rext20

Table of Contents