Your system
administrator generally
has information on pin
1 orientation for tray
and tape input.
PSV5000 Operator's Manual
Setting Up Device Trays and Reject Bin
Static trays (no Tray Feeder) are installed using magnets to hold them in
place. The standard setup is described below.
Make sure that the correct devices for the target job are
loaded into the input tray and that they have the correct pin 1 orien-
tation. (If pin 1 orientation doesn't match pin 1 that is set in the
Package File it must be corrected).
On the PSV5000, Pin 1 on Data I/O sockets is toward the left side of
the Socket Adapter (viewed from the front of the machine).
Orientation of Trays
FOR TRAYS ORIENTED with the long side parallel to the Y-axis, orient the
input and output trays with the beveled corner to the near right.
• The input tray goes on the right closest to machine center.
• The output tray installs on the far left mount.
• If a reject tray is used, install it on the left.
■ List of Steps to Start a Job ≡ Installing Input/Output Media
- 15 -
Need help?
Do you have a question about the PSV5000 and is the answer not in the manual?
Questions and answers