Vent Configuration: Vertical Termination

Use 4x6-5/8" Diameter Coaxial Vent. Connect a 8" to 6-5/8" reducer directly to the fireplace (sku
98900165).
NOTE: The included thimble assembly is not required and may be discarded.
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions.
Up to four elbows (30°, 45°, 60° or 90°) may be used. Only one horizontal elbow may be used.
This is considered a
horizontal elbow (it doesn't
matter whether it turns right
or left). It may be a 30°, 45°,
60°, or 90° elbow.
© Travis Industries
Installation
(for qualified installers only)
H2
H1
Horizontal length is calculated by
adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is
considered a
vertical elbow.
4/22/21 - 1493