Finalizing The Installation; Mv Units Only - Pilot Flame Inspection; Instructions; Gsb2 Units Only - Pilot Flame Inspection - FireplaceXtrordinair ProBuilder 42 CleanFace Installation Manual

Hide thumbs Also See for ProBuilder 42 CleanFace:
Table of Contents

Advertisement

42

Finalizing the Installation

1. Remove the glass (see page 48).
NOTE:
If using propane (LP) convert the appliance prior to installing the media.
2. We recommend you purge the gas line at this time (with the glass removed). This allows gas to be detected
once it enters the firebox, ensuring gas does not build up.
GSB2 Versions Only
Install the batteries into the battery holder
GSR2 Versions Only
Install the batteries into the battery box and remote.
3. Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot to verify gas
supply (see instructions on page 44). Leak test all the gas joints. Turn the gas control knob to "OFF" to shut
off the appliance.
MV Units Only - Pilot Flame Inspection - (see instructions on page 45)
The pilot flame should look like the illustration below. Adjust the pilot flame if necessary.
GSB2 Units Only - Pilot Flame Inspection - (see instructions on page 45)
The pilot flame should look like the illustration below. Adjust the pilot flame if necessary.
The pilot flame should look like the illustration to the right.
Adjust the pilot flame if necessary.
To adjust the pilot flame, turn this screw. Clockwise lowers
the flame while counter-clockwise raises it
4. Replace the glass.
© Travis Industries
Installation
(for qualified installers only)
The pilot flame should touch the top 3/8" of the
sensing electrode and make contact with the pilot
hood. Adjust the pilot up or down as necessary.
Sensing
electrode
4/22/21 - 1493
Pilot Hood
Spark
Electrode
PB42 CF Install

Advertisement