Optional Equipment

Vent Configurations

Minimum Vent Configuration

Use 5x8" Diameter Coaxial Vent
NOTE: Use the included thimble assembly whenever passing through a wall. (use on front and back of wall
penetration). See picture below.
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions.
One elbow (30° or 45°) may be used on the horizontal run.
HINT: Use minimum vent kit "H" (96200332) from Travis Industries (additional vent may be required).
Use the included wall thimble when
penetrating a wall. Part #96200101
© Travis Industries
(for qualified installers only)
4/22/21 - 1493
27
PB42 CF Install