Finalizing the Installation

Top Vent Configuration with Vertical Termination

The termination must fall
within the shaded area
shown in the chart. Use
the indicated restrictor
and diffuser positions.
Up to four elbows (30°,
45°, 60° or 90°) may be
used.
Only one horizontal
elbow may be used.
Use 6-5/8" diameter
vent. Attach the 8" to 6-
5/8" reducer (Travis part
# 98900165) to the
fireplace.
This is considered a
horizontal elbow (it doesn't
matter whether it turns right
or left). It may be a 30°, 45°,
60°, or 90° elbow.
© Travis Industries
40' max (12m)
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
Exhaust Restrictor # 1
Intake Restrictor # 2
Diffuser Position # 2
10 feet (3m)
5 feet (1.5m)
Attach 6-5/8" Reducer
Directly to Fireplace
0 feet
H2
H1
4/23/2021 - 1552
(for qualified installers only)
Exhaust Restrictor # 3
Intake Restrictor # 3
Diffuser Position # 2
Exhaust Restrictor # 2
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 1
Intake Restrictor # 1 (stock)
Diffuser Position # 1
Horizontal length is calculated by
adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is
considered a
vertical elbow.
40' max (12m)
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
564 GSR2 35K CF