Finalizing the Installation

Vent Configuration - Horizontal Termination

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Up to four elbows (30°, 45°, 60° or 90°) may be used.
Use 8" (203mm) diameter vent (see page for 21 details).
Only one horizontal elbow may be used.
NG Installations require 1' Vertical Vent Section Directly off Top of Fireplace
LP Installations require 2' Vertical Vent Section Directly off Top of Fireplace
NOTE: If removing the restrictor, make sure to replace the screws in the firebox ceiling.
This is considered a
horizontal elbow (it doesn't
matter whether it turns right
or left). It may be a 30°, 45°,
60°, or 90° elbow.
© Travis Industries
(for qualified installers only)
H2
Horizontal length is calculated by
adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is
H1
considered a
vertical elbow.
4/23/2021 - 1480
864 40K Install