Wall Mount Remote Thermostat installation (GSB2 and MV Units Only)

Packing List
GS Wall Remote
Receiver Assembly
Switch Blank
Installation
If Using the Optional Blower, Install it First
The optional blower should be installed before installing the remote.
1
Remove the lower front access panel from the fireplace by reaching in behind it and loosening the two wing
nuts and (1) ¼" screw on each side of the panel that hold it in place (see fireplace manual for details.) Lift up
and then out on the panel to remove. Lay the panel face down in front of the fireplace.
2
Remove the 4 screws that secure the dashboard to the fireplace and gently lower it to gain access to the back
side.
NOTE
There should be enough slack in the attached wires to lower the dashboard to the floor. Make sure not
to damage any off the attached wires.
3
Remove the two wires from the back of the on/off switch.
© Travis Industries