Rack Cabling Access
ESR3 racks have removable top and bottom access panels.
Conduit Connections
Step 1:
Step 2:
Step 3:
Step 4:
.
WARNING:
Trunking or Wire Trough Connections
Step 1:
Step 2:
Step 3:
Step 4:
Note:
Step 5:
Installation of Racks
Top access panel
Remove the desired access panel from the rack.
Cut access holes in the top and bottom access panels.
Install your cabling into the holes.
Re-install the access panel so that there are minimal air gaps.
Leaks" on page 30.
for more information
Cutting holes in the rack plates in situ may introduce metal debris
into the dimmer cabinet.
Remove the desired access panels.
Cut suitable openings to mate with the trunking or trough using a jigsaw or hacksaw.
Reinstall panel on to rack
Install a fiche paper lining or grommeting material in the access panel opening.
Wire openings must have fittings or linings to protect cable insulation from damage
by sharp metal edges.
Position the trunking or wire trough above the prepared opening.
Figure 7: ESR3 access panels
Bottom access panel
See "Sealing Rack Air
15