ETC Sensor+ SR Series Retro-Fit Manual
ETC Sensor+ SR Series Retro-Fit Manual

ETC Sensor+ SR Series Retro-Fit Manual

Cem+ sensor rack

Advertisement

CEM+ Sensor Rack (SR Series)
Retrofit Manual
Revision A
C o p y r i g h t © E le c tr o n i c T h e a t r e C o n t r o l s , I n c .
A l l R i g h t s r e s e r v e d .
P r o d u c t in f o r m a t i on a n d s p e c i f i c a t i o n s s u bj e c t t o c h a n g e .
P a r t N u m b e r : 7150M2300 R e v A
R e l e a s e d : J u n e 2 0 0 4

Advertisement

Table of Contents
loading

Summary of Contents for ETC Sensor+ SR Series

  • Page 1 CEM+ Sensor Rack (SR Series) Retrofit Manual Revision A C o p y r i g h t © E le c tr o n i c T h e a t r e C o n t r o l s , I n c . A l l R i g h t s r e s e r v e d .
  • Page 2 ® ® ® ET C , E m p h a s i s ™ , E x p r e s s i o n , I n s i gh t ™ , I m a g i n e ™ , F o c u s ™ , E x p r e s s ™ , U n i s o n ®...
  • Page 3 Introduction This manual is intended to guide ETC Service Technicians through the process of upgrading existing Sensor rack installations to Sensor+ racks with an CEM+ control module. This manual covers SR6, SR12, SR24 and SR48 permanent installation dimming racks. If you have questions about the retrofit process that are not answered in this manual, please contact ETC Technical Services.
  • Page 4: Table Of Contents

    S a f e t y Please note the following safety warnings before use: • Disconnect power from the racks before all maintenance. W A R N I N G : Dimmer racks without an accessible power disconnect device cannot be serviced safely.
  • Page 5 The table below lists the parts and components needed to retrofit a Sensor rack up to a Sensor+ rack with a CEM+. Each part is listed to reflect the different quantities for the different kits and types of racks. Parts/Components ETC Part Number CEM+ Backplane Bracket 7150A3002 CEM+ Backplane PCB Assy...
  • Page 6 Parts/Components ETC Part Number Sensor+ AF Cards (Optional) 7150B5005 Terminal Block 8F Plug IDC (Optional) J3409 CEM+ 7150A1001 Required Tools #1 Phillips screwdriver #2 Phillips screwdriver 3/8” Socket Diagonal wire cutter Permanent marker Heat shink gun CEM+ Sensor Rack Retrofit Manual...
  • Page 7: Preparation

    This connector will be used in the upgrade. Step 7: Unscrew the backplane metal from the rack. (One screw in each side upper- corner - two screws total.) Discard these screws. Replacement screws with thread locker are provided (ETC Part# HW377). The Retrofit...
  • Page 8 Belden 9729 and contains screw terminals (ETC Part# J3407- included with the kits). The other style is an IDC connector (ETC Part# J3409 - an additional line item) for solid-core wire such as Category 5 cabling.
  • Page 9 Step 5: Install the power adapter harness to edge connector (straight thru PCB) to old power connector (match the wire colors) The PCB is the same on both sides, top and bottom. Wire-tie the connectors together Match the wire colors Step 6: Secure the power connectors together with provided 4"- wire-ties.
  • Page 10 On bottom for Lower Step 11: Terminate the Ethernet cable with the provided Ethernet Termination Kit (ETC Part# 4101A2003). Follow the wire preparation and termination instructions included with the kit. CEM+ Sensor Rack Retrofit Manual...
  • Page 11: Install The New Backplane

    I n s t a l l t h e N e w B a c k p l a n e Step 1: Set the DMX termination switches. Termination should be turned on for the last physical rack in the DMX daisy- chain (No DMX wiring goes back out for that port.) The switches and their location are shown here.
  • Page 12: Change Out The Af Cards (If Present)

    PCB with the connector in the same orientation. Step 5: Install the new beacon PCB (ETC Part # 7050B5109) with two screws (ETC Part # HW222) (two new screws of the same type are provided in case the old ones get damaged during the removal process).
  • Page 13: Verify The Retrofit

    F i n i s h i ng T o u c h e s Step 1: Remove the old Sensor beacon acrylic in the door and discard. Step 2: Install the Sensor+ beacon acrylic in the door. Step 3: Remove old Sensor label from the front of the door and discard.
  • Page 14 CEM+ Sensor Rack Retrofit Manual...
  • Page 15: Quick Reference Sheet

    Quick Reference Sheet...
  • Page 16 CEM+ Sensor Rack Retrofit Manual...
  • Page 17 Notes: Quick Reference Sheet...
  • Page 18 Notes: CEM+ Sensor Rack Retrofit Manual...
  • Page 20 Americas 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA Tel: +1 608 831 4116 800 688 4116 Fax: +1 608 836 1736 800 555 8912 Europe Unit 5, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK Tel: +44 (0)20 8896 1000 Fax: +44 (0)20 8896 2000 Asia Room 605-606, Tower III Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong Tel: +852 2799 1220 Fax: +852 2799 9325 Web: www.etcconnect.com...

This manual is also suitable for:

Sensor+ sr6Sensor+ sr12Sensor+ sr24Sensor+ sr48

Table of Contents