I n s t a l l a t i o n G u i d e
®
Unison Paradigm
O v e r v i e w
The Unison Paradigm
which is shipped separately. It is powered by either LinkPower with auxiliary power or by PoE (Power
over Ethernet 802.3af).
• Echelon
24 Vdc Auxiliary power (two 16 AWG 1.5mm
• PoE (Power Over Ethernet 802.3af) using Category 5 cable (or approved equal).
Control wiring should only be installed and terminated by a qualified technician and should follow
standard wiring installation practices. Leave approximately 10 inches (254mm) of wiring in the backbox
for connection and to allow slack for future service needs. For more information about terminating CAT5
cable, refer to the ETC Ethernet Cat5 Termination Kit Setup Guide.
I n s t a l l C o l l a r i n R a c k P a n e l
Installation should follow local codes and standard practices. Ensure that all wiring is installed correctly.
The touchscreen is supplied with an installation kit which includes the necessary hardware and
electrical supplies.
Paradigm Touchscreen Model
Model
P-TS7-RM
Mounting
Pin
Step 1:
N o t e :
Step 2:
Corporate Headquarters
London, UK
Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK
Rome, IT
Via Pieve Torina, 48, 00156 Rome, Italy
Holzkirchen, DE
Hong Kong
Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong
Service: (Americas)
Web:
www.etcconnect.com
7184M2190
Rev A
P-T S7 Rack Pa ne l
®
P-TS7 Rack Panel
®
P-TS7 Touchscreen can be installed in an equipment rack using a rack panel,
®
®
LinkPower
(LinkConnect) control network using Belden 8471 (or approved equal) and
Paradigm Touchscreen Rack Panel
Slide the collar into the rack panel.
It is important to orient the rack panel with the cutout on the right side to provide better
cable access between the touchscreen and the Termination PCB.
In addition, the collar should be installed with the stamped arrow (
Install and tighten four M4 x 20mm collar mount screws through the collar and into the
rack panel.
3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA
Tel +39 (06) 32 111 683
Ohmstrasse 3, 83607 Holzkirchen, Germany
service@etcconnect.com
(UK)
service@etceurope.com
Copyright © 2015 ETC. All Rights Reserved.
Released 2015-01
ETC intends this document to be provided in its entirety.
2
) wires.
Description
Cutout on
right side
Tel +44 (0)20 8896 1000
Fax +44 (0)20 8896 2000
Tel +49 (80 24) 47 00-0
Fax +49 (80 24) 47 00-3 00
(DE)
techserv-hoki@etcconnect.com
Product information and specifications subject to change.
Pag e 1 of 4
) pointing up.
Tel +608 831 4116
Fax +608 836 1736
Fax +44 (0)20 8896 2000
Tel +852 2799 1220
Fax +852 2799 9325
(Asia)
service@etcasia.com
El ect r on ic T he at r e Con t ro ls , I nc .

Advertisement

loading

Summary of Contents for ETC Unison Paradigm P-TS7

  • Page 1 For more information about terminating CAT5 cable, refer to the ETC Ethernet Cat5 Termination Kit Setup Guide. I n s t a l l C o l l a r i n R a c k P a n e l Installation should follow local codes and standard practices.
  • Page 2 Only one network type (LON or Ethernet) may be connected to the touchscreen at a time. Do not connect both Auxiliary power and PoE. ETC requires that all backboxes and touchscreens are grounded in accordance with local electrical codes. The RJ11 connection must be used to provide a ground connection from the backbox to the touchscreen even when Ethernet connectivity is used.
  • Page 3 E T C I n s t a l l a t i o n G u i d e P-TS7 Rack Panel RJ11 connector (provides LinkPower and RJ45 Ethernet with Aux power to touchscreen) (PoE to touchscreen) 24 Vdc Aux RJ45 power Mounting bracket...
  • Page 4 E T C I n s t a l l a t i o n G u i d e P-TS7 Rack Panel Step 2: Plug the other end of the cable(s) into the receptacles on the touchscreen. The touchscreen bracket is designed for two positions, service and operation.