7. Locate the DIMM slot for installation.
8. Ensure that the DIMM ejection tabs at both ends of the DIMM slot are pushed outward to the open
position (see Letter A).
9. Carefully unpack the replacement DIMM, taking care to only handle the device by its outer edges.
10. Align the notch at the bottom edge of the Memory Module with the key in the DIMM slot
(see Letter B).
11. Insert the Memory Module into the slot (see Letter C), push down on the DIMM until the ejection tabs
snap into place (see Letter D).
12. Ensure that the ejection tabs are firmly in place (see Letter E).
13. Reinstall the system top cover (see
72
Figure 80. Memory Module Installation
Section
6.1.2).