Intel Sas Raid Module Removal - Intel M50CYP1UR Series Integration And Service Manual

Server system
Table of Contents

Advertisement

Intel® Server System M50CYP1UR Family System Integration and Service Guide
3.8.4
Intel® SAS RAID Module Removal
1.
Power off the system and disconnect the power cable(s).
2.
Remove the system top cover (see
3.
Disconnect all the cables connected to the SAS RAID module.
4.
Remove the four locking pins from each standoff (see Letter A).
5.
Grasp the SAS RAID module on both sides and pull up firmly until the connector is disengaged from the
matching connector on the SAS interposer card (see Letter B).
6.
Remove the standoffs (see Letter C), if not installing another SAS RAID module on the SAS interposer
card. Keep the standoffs, locking pins, and the SAS RAID module together.
7.
Reinstall the system top cover (see
3.9
Intel® RAID Maintenance Free Backup Unit (RMFBU) and Mounting Bracket
Installation / Removal
This section provides instructions to install an RMFBU bracket and assembly in the system. Refer to the Intel®
Server M50CYP Family Configuration Guide for available options.
Required Tools and Supplies
Anti-static wrist strap and conductive workbench pad (recommended)
Phillips* head screwdriver #1
The RMFBU assembly has the following elements:
Latch
Supercap capacitor
RMFBU plastic case
The RMFBU bracket and assembly are installed in the same area inside the chassis as the SAS interposer
card (see
Section
3.8).
The three elements need to be assembled before attaching to the mounting bracket.
Figure 58. Intel® SAS RAID Module Removal
Section
3.1.1).
Section
3.1.2).
57