ABB JDF300 Operating Instruction page 20

Field indicator with foundation fieldbus communication
Table of Contents

Advertisement

20
J D F 3 0 0 | F I E L D I N D I C ATO R | O I/ J D F 3 0 0 - E N R E V. B
. . .RESOURCE Block Mapping
Idx
Parameter
21
MIN_CYCLE_T
22
MEMORY_SIZE
23
NV_CYCLE_TIME
24
FREE_SPACE
25
FREE_TIME
26
SHED_RCAS
27
SHED_ROUT
28
FAULT_STATE
29
SET_FSTATE
30
CLR_FSTATE
31
MAX_NOTIFY
32
LIM_NOTIFY
33
CONFIRM_TIME
34
WRITE_LOCK
35
UPDATE_EVT
36
BLOCK_ALM
37
ALARM_SUM
38
ACK_OPTION
39
WRITE_PRI
40
WRITE_ALM
41
ITK_VER
42
CB_SW_REV
43
CB_HW_REV
44
CAPABILITY_LEV
45
COMPATIBILITY_REV
46
FD_VER
47
FD_FAIL_ACTIVE
48
FD_OFFSPEC_ACTIVE
49
FD_MAINT_ACTIVE
50
FD_CHECK_ACTIVE
51
FD_FAIL_MAP
52
FD_OFFSPEC_MAP
53
FD_MAINT_MAP
54
FD_CHECK_MAP
55
FD_FAIL_MASK
56
FD_OFFSPEC_MASK
57
FD_MAINT_MASK
58
FD_CHECK_MASK
Description / Range / Selections / Notes
Time duration of the shortest cycle interval of which the resource is capable.
Available configuration memory in the empty resource. To be checked before attempting a download
Min. time interval for writing copies of NV parameters to non-volatile memory. Zero means it will be never
automatically copied.
Percent of memory available for further configuration. Zero in a preconfigured device
Percent of the block processing time that is free to process additional blocks.
Time duration at which to give up on computer writes to function block Rcas locations. Shed from Rcas shall never
happen when Shed_Rcas = 0
Time duration at which to give up on computer writes to function block Rout locations. Shed from Rout shall never
happen when Shed_Rout = 0
Fault State
Set Fault State
Clear Fault State
Maximum number of unconfirmed alert notify messages possible
Maximum number of unconfirmed alert notify messages allowed
The min time between retries of alert report. Retries shall not happen when Confirm_Time = 0
1
Unlocked (default)
2
Locked
This alert is generated by any change to the static data
The block alarm is used for all configuration, hardware, connection failure or system problems in the block. The cause
of the alert is entered in the subcode field. The first alert to become active will set the Active Status in the status
parameter. As soon as the Unreported status is cleared by the alert reporting task, another block alert may be
reported without clearing the Active Status, if the subcode has changed
The alert status associated to the function block
0
Auto Ack Disabled (default)
1
Auto Ack Enabled
Priority of the alarm generated by clearing the write_lock
This alert is generated if the write_lock parameter is cleared
6
"XX.YY.ZZ" (08.01.01)
"XX.YY.ZZ" (01.00.00)
Not Supported
0x01
Indicates value of major version of instrument diagnostics specifications (FF-912).
Active error conditions of Failure category
Active error conditions of Out of Specification category
Active error conditions of Maintenance category
Active error conditions of Check Function category.
Errors Mapped as Failure
Errors Mapped as Out of Spec
Errors Mapped as Maintenance:
Errors Mapped as Function Check
Fail error to be masked
Out of Spec errors to be masked
Maintenance errors to be masked
Function Check errors to be masked
If set, no writes are allowed except to clear Write_Lock.
Block inputs will continue to be updated
Selection of whether alarms associated the function block
will be automatically acknowledged
According to the NAMUR NE107 Categories.
Bit x = 0 – Error Clear
Bit x = 1 – Error Active
It is a bit-string so that multiple errors of the list below
may be shown.
Default mapping: Bit 4 Electronic memory fail
Default mapping: none
Bit 2 MAO not Scheduled
Default mapping:
Bit 3 MAO inputs all disabled
Bit 5 NV memory burn error
Bit 0 Function Check
Default mapping:
Bit 1 MAO in OOS
Default no error masked