7.1. CABLES

Check the condition of welding and connection cables daily. Do not use faulty cables!
Make sure that the mains connection cables in use are safe and according to regulations!
The repair and mounting of mains connection cables should be carried out only by an authorized
electrician.

7.2. POWER SOURCE

NOTE! Disconnect the plug of the power source from the mains socket before removing the
cover plate.
Check at least every 6 months (twice a year):
-
Electric connections of the unit - clean the oxidized parts and tighten the loosened ones.
NOTE! You must know correct tension torques before starting the repair of the joints.
-
Clean the inner parts of the machine from dust and dirt e.g. with soft brush and vacuum
cleaner.
Do not use compressed air. Do not use pressure washing device!
-
There is a risk that dirt is packed even more tightly into gaps of components!
Only authorized electrician shall carry out repairs to the machines.

8. REGULAR MAINTENANCE OF THE EQUIPMENT

Kemppi service repair shops make regular maintenance according to the agreement.
The major points in the maintenance procedure are listed as follows:
-
Cleaning of the machine
-
Checking and maintenance of the welding tools
-
Checking of connectors, switches and potentiometers
-
Checking of electric connections
-
Metering units checking
-
Checking of mains cable and plug
-
Damaged parts or parts in bad connection are replaced by new ones
-
Maintenance testing. Operation and performance values of the equipment are checked,
and adjusted when necessary by means of test equipment.
The amount of use and the working environment should be taken into consideration when plan-
ning the frequency of maintenance of the machine. Careful use and preventive maintenance will
help to ensure trouble-free operation.

9. ORDERING NUMBERS

Kempomat 2500 230 / 400
Kempomat 3200 230 / 400 V
Kempomat 4000 230 V
Kempomat 4000 400 V
KMW timer (Timer unit)
KMW sync (Synchronization unit)
MSD 1 (Volt / Ampere metering unit)
GH 20 (Gun holder)
Hub for wire reel
MT 25
3 m
MT 25
4,5 m
MT 32
3 m
MT 32
4,5 m
KMG 25
3 m
KMG 25
4,5 m
KMG 32
3 m
KMG 32
4,5 m
MMT 25
3 m
MMT 25
4,5 m
COPYRIGHT KEMPPI OY
621425001
621432001
621440201
621440401
6219200
6219100
6185666
6256020
4289880
6252023
6252024
6253023
6253024
6252123
6252124
6253033
6253034
6252513MMT
6252514MMT
Kempomat 2500, Kempomat 3200, Kempomat 4000 / 0340 / 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kempomat 3200Kempomat 4000

Table of Contents