10. TECHNICAL DATA

Kempomat 2500
Rated voltage
Connection voltage
3~ 400 V
3~ 230 V
Connection capacity
230 V / 400 V
*) ED
60 % ED
100 % ED
Loading capacity
(nominal values)
*) ED
60 % ED
100 % ED
Control range
Voltage steps
Open circuit voltage max.
Efficiency
Power factor
Fuse
Wire feeder unit
Diameter of feed roll
Wire feed speed
Filler wires
ø Fe, Ss
ø Cored wire
ø Al
Wire reel
max. weight
max. size
Gun connector
Temperature class
Operation temperature range
Storage temperature range
Degree of protection
External dimensions
length
width
height
Weight
The products meet conformity requirements for CE marking.
COPYRIGHT KEMPPI OY
230 V / 400 V
380 V -10 %...415 V +6 %
220 V -10 %...240 V +6 %
9.2 kVA *) 30 %
5.9 kVA
4.0 kVA
250 A / 26 V *) 30 %
180 A / 23 V
140 A / 21 V
40 - 250 A / 14 - 26 V
10 steps
35 V
250 A / 26 V 75 %
250 A / 26 V 0.95
8 A delayed
2-roll drive
32 mm
0...18 m / min
0,6...1,2 mm
0,8...1,2 mm
1,0...1,2 mm
20 kg
ø 300 mm
Euro
H (180 °C)
-20...+40 °C
-40...+60 °C
IP 23C
930 mm
440 mm
860 mm
80 kg
Kempomat 2500, Kempomat 3200, Kempomat 4000 / 0340 / 21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kempomat 3200Kempomat 4000