Electrical Installation - Emerson Rosemount 702 Reference Manual

Wireless discrete transmitter for plunger arrival
Hide thumbs Also See for Rosemount 702:
Table of Contents

Advertisement

Figure 3-1:
A. LCD pins
B. LCD display
C. LCD cover
3.3

Electrical installation

Making electrical connections
Make electrical connections through the cable entry in the side of the connection head.
Cabling/conduit may vary depending on installation practices; cabElecle glands are
available to order as an option on the 702. Contact your local sales representative if cable
glands are needed. Be sure to provide adequate clearance for cover removal. Make sure to
route the sensor wiring so that the power module installation is not obstructed.
Wiring the arrival sensor
The Rosemount 702 Transmitter has screw terminals corresponding to each of the plunger
arrival sensor's wiring terminals. These terminals are labeled as follows:
PWR OUT:
SIG:
COM:
Reference Manual
LCD Display
A
Power out to the arrival sensor
Input signal from the arrival sensor
Common ground for both the power output and the signal
B
C
Installation
39