Transmitter
An installation-ready solution that provides simple connection to a turbine
meter.
Measures average flow and totalized volume.
Flow and volume are continuously measured between wireless updates.
Self-organizing network delivers information rich data with >99 percent data
reliability totalized volume.
705 Wireless Totalizing
Quick Start Guide
00825-0200-4705, Rev DA
April 2019

Advertisement

loading

Summary of Contents for Emerson Rosemount 705

  • Page 1 Quick Start Guide 00825-0200-4705, Rev DA April 2019 ™ Rosemount 705 Wireless Totalizing Transmitter An installation-ready solution that provides simple connection to a turbine  meter. Measures average flow and totalized volume.  Flow and volume are continuously measured between wireless updates. ...
  • Page 2: Table Of Contents

    April 2019 Quick Start Guide NOTICE This guide provides basic guidelines for the Rosemount 705 Transmitter. It does not provide instructions for detailed configuration, diagnostics, maintenance, service, troubleshooting, or installations. Refer to the Rosemount 705 Reference Manual for more instruction. This guide and the manual are available electronically on Emerson.com/Rosemount.
  • Page 3: Seal And Protect Threads

    Mount transmitter on a turbine meter or pulse output device General considerations The Rosemount 705 Transmitter and all other wireless devices should not be set up until after the Smart Wireless Gateway (Gateway) has been installed and is functioning properly.
  • Page 4 April 2019 Quick Start Guide Direct mount Figure 2. Direct Mount A. Rosemount 705 Transmitter B. 1-in. NPT connection to flow meter and two-piece pipe union C. Turbine meter Note Direct mount installation should not be employed when using tubing and connectors such ®...
  • Page 5 Quick Start Guide April 2019 3. Attach the transmitter housing to the turbine meter using the threaded conduit entry. 4. Seal threads on 1-in. NPT turbine meter connection. Take union apart and turn on bottom fitting to turbine meter. 5. Attach mill spec connector to turbine meter pickup. 6.
  • Page 6 April 2019 Quick Start Guide Remote mount Figure 4. Remote Mount A. Rosemount 705 Transmitter B. 1-in. supplied cable gland adaptor for turbine meter C. Turbine meter 1. Install the turbine meter according to standard installation practices making sure to use thread sealant on all connections.
  • Page 7 ™ If the supplied remote mount antenna kit is not installed per these instructions, Emerson is not responsible for wireless performance or non-compliance with spectrum regulations.
  • Page 8 Note: Weatherproofing The remote mount antenna kit includes coaxial sealant for weatherproofing the cable connections for the lightning arrestor, antenna, and Rosemount 705 Transmitter. Coaxial sealant must be applied to ensure performance of the wireless field network. See Figure 6 for details on how to apply coaxial sealant.
  • Page 9: Connect To Device

    Quick Start Guide April 2019 Connect to device Figure 7. Device Connection A. Communication terminals B. Field Communicator C. HART Modem D. AMS Device Manager Field Communicator connections The power module needs to be installed before the Field Communicator can interface with the transmitter.
  • Page 10: Mount Transmitter On A Turbine Meter Or Pulse

    2. Wait for communication status to become Connected. Note This takes several minutes. Enable Active Advertising on the Gateway to ensure new devices are able to join the network faster. For more information see the Emerson Wireless Gateway Reference Manual.
  • Page 11: Product Certifications

    All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.
  • Page 12 ™ For use with Rosemount SmartPower power module part number 753-9220-0001, or for use with Emerson SmartPower option 701PBKKF. See the table at the end of this section for entity parameters. Special Conditions for Safe Use (X): 1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
  • Page 13 ≤ +70 °C) Markings: For use with Rosemount SmartPower power module part number 753-9220-0001, or for use with Emerson SmartPower option 701PBKKF. See the table at the end of this section for entity parameters. Special Conditions for Safe Use (X): 1.
  • Page 14 April 2019 Quick Start Guide Special Conditions for Safe Use (X): 1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth. 2.
  • Page 15 Quick Start Guide April 2019 Figure 8. Rosemount 705 Declaration of Conformity EU Declaration of Conformity No: RMD 1105 Rev. G Rosemount, Inc. 8200 Market Boulevard Chanhassen, MN 55317-9685 declare under our sole responsibility that the product, Rosemount™ 705 Wireless Totalizer Transmitter manufactured by, Rosemount, Inc.
  • Page 16 April 2019 Quick Start Guide EU Declaration of Conformity No: RMD 1105 Rev. G EMC Directive (2014/30/EU) Harmonized Standards: EN 61326-1: 2013 Radio Equipment Directive (RED) (2014/53/EU) Harmonized Standards: EN 300 328 V2.1.1 EN 301 489-1 V2.2.0 EN 301 489-17 V3.2.0 EN 61010-1: 2010 EN 62311: 2008 ATEX Directive (2014/34/EU)
  • Page 17 Quick Start Guide April 2019 China RoHS Rosemount 705 List of Rosemount 705 Parts with China RoHS Concentration above MCVs / Hazardous Substances Hexavalent Polybrominated Polybrominated Part Name Lead Mercury Cadmium Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr +6)
  • Page 18 April 2019 Quick Start Guide...
  • Page 19 Quick Start Guide April 2019...
  • Page 20 Emerson FZE P.O. Box 17033 and Conditions of Sale page. Jebel Ali Free Zone - South 2 The Emerson logo is a trademark and service mark of Emerson Dubai, United Arab Emirates Electric Co. +971 4 8118100 Rosemount and Rosemount logotype are trademarks of Emerson.