Wireless Considerations
Step 1: Physical Installation
Step 2: Device Network Configuration
Step 3: Verify Operation
Product Certifications
EC Declaration of Conformity
Start
End
Rosemount 708

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Rosemount 708

  • Page 1 Quick Installation Guide 00825-0200-4708, Rev AD Rosemount 708 April 2012 Rosemount 708 Wireless Acoustic Transmitter Start Wireless Considerations Step 1: Physical Installation Step 2: Device Network Configuration Step 3: Verify Operation Product Certifications EC Declaration of Conformity www.rosemount.com...
  • Page 2: Important Notice

    © 2012 Rosemount Inc. All rights reserved All marks property of owner. Standard Terms and Conditions of Sale can be found at www.rosemount.com/terms_of_sale The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
  • Page 3 00825-0200-4708, Rev AD Rosemount 708 April 2012 Rosemount 708 Wireless Acoustic Transmitter Overview 1. Power Module cover – Location of Power Module in device. Unscrew cap for access to Power Module. 2. Waveguide – Location of the acoustic and temperature sensors.
  • Page 4: Wireless Considerations

    Quick Installation Guide 00825-0200-4708, Rev AD Rosemount 708 April 2012 IRELESS ONSIDERATIONS Power Up Sequence The Smart Wireless Gateway should be installed and functioning properly before any wireless devices are powered. Install the Power Module, Smart Wireless 701PGNKF into the 708 to power the device. This results in a simpler and faster network installation.
  • Page 5: Step 1: Physical Installation

    Quick Installation Guide 00825-0200-4708, Rev AD Rosemount 708 April 2012 1: P HYSICAL NSTALLATION The acoustic transmitter is connected directly to the piping that is being measured. Mounting 1. Locate the 708 on a horizontal section of piping as close as possible to the equipment to be monitored.
  • Page 6: Mounting Considerations

    Quick Installation Guide 00825-0200-4708, Rev AD Rosemount 708 April 2012 Power Module Installation Figure 5. NOTE: Wireless devices should be powered up in order of proximity from the Smart Wireless Gateway, beginning with the closest device to the Smart Wireless Gateway. This will result in faster network formation.
  • Page 7: Field Communicator

    Quick Installation Guide 00825-0200-4708, Rev AD Rosemount 708 April 2012 2: D EVICE ETWORK ONFIGURATION In order to communicate with the Smart Wireless Gateway, and ultimately the Information System, the transmitter must be configured to communicate with the wireless network. This step is the wireless equivalent of connecting wires from a transmitter to the host system.
  • Page 8: Step 3: Verify Operation

    Suite Wireless Configurator or AMS Device Manager. If the Rosemount 708 was configured with the Network ID and Join Key, and sufficient time has passed, the transmitter will be connected to the network. If Network ID and Join Key were not configured, please reference Troubleshooting on page 9.
  • Page 9 When the device has joined the network, it will appear in the Device Manager as illustrated in Figure 9. For HART Wireless transmitter communication, a 708 DD is required. To obtain the latest DD, visit the Emerson Process Management Easy Upgrade site at: http://www2.emersonprocess.com/en-US/documentation/deviceinstallkits.
  • Page 10 Quick Installation Guide 00825-0200-4708, Rev AD Rosemount 708 April 2012 Field Communicator Use NOTE In order to communicate with a Field Communicator, power the 708 by connecting the Power Module. For more information on the Power Module, refer to the Power Module product data sheet (Document No 00813-0100-4701).
  • Page 11: Product Certifications

    RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.
  • Page 12 Enclosure Type 4X / IP66/67 Special Conditions for Safe Use (X): 1. The Rosemount 708 Wireless Acoustic Transmitter shall only be used with the SmartPower Solutions, model number 701PGN green power module. 2. Potential Electrostatic charging Hazard – See Instructions.
  • Page 13 For use with SmartPower Solutions, model number 701PGN green power module only. Special Conditions for Safe Use (X): 1.The engineered polymer enclosure of the Rosemount 708 may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth.
  • Page 14: Ec Declaration Of Conformity

    Quick Installation Guide 00825-0200-4708, Rev AD Rosemount 708 April 2012 EC Declaration of Conformity No: RMD 1084 Rev. C Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317-6985 declare under our sole responsibility that the product, Model 708 Wireless Acoustic Transmitter manufactured by, Rosemount Inc.
  • Page 15 Quick Installation Guide 00825-0200-4708, Rev AD Rosemount 708 April 2012 EC Declaration of Conformity No: RMD 1084 Rev. C EMC Directive (2004/108/EC) All Models with ”Operating Frequency and Protocol Code 3” EN 61326-2-3:2006 R&TTE Directive (1999/5/EC) All Models with ”Output Code X” and ”Operating Frequency and Protocol Code 3”...
  • Page 16 Quick Installation Guide 00825-0200-4708, Rev AD Rosemount 708 April 2012 EC Declaration of Conformity No: RMD 1084 Rev. C ATEX Notified Bodies for EC Type Examination Certificate Baseefa. [Notified Body Number: 1180] Rockhead Business Park Staden Lane Buxton, Derbyshire SK17 9RZ United Kingdom ATEX Notified Body for Quality Assurance Baseefa.

Table of Contents