Rosemount 705 Wireless Totalizing
Transmitter
An installation-ready solution that provides simple and easy connection to a
pulse source
Measure average flow and totalized volume
Flow and volume are continuously measured between wireless updates
Self-organizing network delivers information rich data with >99% data
reliability totalized volume
Quick Start Guide
00825-0200-4705, Rev AA
August 2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rosemount 705 and is the answer not in the manual?

Questions and answers

Summary of Contents for Emerson Rosemount 705

  • Page 1 Quick Start Guide 00825-0200-4705, Rev AA August 2014 Rosemount 705 Wireless Totalizing Transmitter An installation-ready solution that provides simple and easy connection to a  pulse source Measure average flow and totalized volume  Flow and volume are continuously measured between wireless updates ...
  • Page 2: Required Equipment

    Wireless Configurator version 12.0 or later, or Field Communicator  NOTICE This guide provides basic guidelines for the Rosemount 705. It does not provide instructions for detailed configuration, diagnostics, maintenance, service, troubleshooting, or installations. Refer to the Rosemount 705 Reference Manual (document number 00809-0200-4705) for more instruction.
  • Page 3: Step 2: Seal And Protect Threads

    Step 3: Mount 705 on pulse input device General considerations Physical installation The Rosemount 705 Totalizer and all other wireless devices should not be set up until after the Smart Wireless Gateway has been installed and is functioning properly. The transmitter can be installed in one of two configurations: Direct Mount, where the pulse output device is connected directly to the ...
  • Page 4: Direct Mount

    August 2014 Quick Start Guide Direct mount Note Direct mount installation should not be employed when using tubing and connectors such as ® Swagelok fittings. 1. Install the pulse output device according to standard installation practices making sure to use thread sealant on all connections. 2.
  • Page 5: Remote Mount

    Quick Start Guide August 2014 a. The antenna should be approximately 3-ft. (0.91 m) from any large structures or buildings, to allow clear communication to other devices. Possible antenna rotation shown. Antenna rotation allows for best installation practices in any configuration.
  • Page 6 August 2014 Quick Start Guide 6. Close the housing cover and tighten to safety specification. Always ensure a proper seal so that metal touches metal, but do not over tighten. 7. Position the antenna vertically and straight up. a. The antenna should be approximately 3-ft. (0.91 m) from any large structures or buildings, to allow clear communication to other devices.
  • Page 7: Remote Antenna (Optional)

    If the supplied remote mount antenna kit is not installed per these instructions, Emerson Process Management is not responsible for wireless performance or non-compliance with spectrum regulations.
  • Page 8 Weather proofing is required! The remote mount antenna kit includes coaxial sealant for weather proofing the cable connections for the lightning arrestor, antenna, and Rosemount 705 Totalizer. Coaxial sealant must be applied to guarantee performance of the wireless field network. See Figure 2 for details on how to apply coaxial sealant.
  • Page 9: Power-Up Sequence

    Quick Start Guide August 2014 Step 4: Insert black power module Power up sequence The Smart Wireless Gateway should be installed and functioning properly before any wireless field devices are powered. Install the Black Power Module, ™ SmartPower Solutions model number 701PBKKF (part number 00753-9220-0001) into the transmitter to power the device.
  • Page 10: Field Communicator Connections

    August 2014 Quick Start Guide Field Communicator 1. Turn on the Field Communicator. 2. Tap the HART symbol on the main menu. The Field Communicator now connects to the device. Field Communicator connections The power module needs to be installed before the Field Communicator can interface with the transmitter.
  • Page 11 Quick Start Guide August 2014 Step 8: Wait for device to join network a. Go to Overview > Status. b. Wait for communication status to become Connected. Note This takes several minutes. The Rosemount 705 Wireless Totalizer has been successfully installed.
  • Page 12: Product Certifications

    Quick Start Guide Product Certifications Approved Manufacturing Locations Rosemount Inc. – Chanhassen, Minnesota, USA Emerson Process Management GmbH & Co. - Karlstein, Germany Emerson Process Management Asia Pacific Private Limited - Singapore European Union Directive Information Telecommunication Compliance FCC and IC...
  • Page 13 Quick Start Guide August 2014...
  • Page 14 © 2014 Rosemount Inc. All rights reserved. All marks property of owner. Instrument Co., Limited The Emerson logo is a trade mark and service mark of Emerson Electric Co No. 6 North Street, Hepingli, AMS, Rosemount, and the Rosemount logotype are registered trademarks of Dong Cheng District Rosemount Inc.