Environmental Specifications - Xycom AHIP-370 Manual

Advanced high-integration platform
Table of Contents

Advertisement

AHIP-370 Manual
abled. If this is not done the system generates a floppy drive error during the POST
(Power On Self Test).
The enhanced IDE (EIDE) interface supports up to 2 hard drives. Hard drive inter-
face is via the Xycom plug-in backplane or the on-board IDE controller.
The higher the PIO mode, the shorter the cycletime. As the IDE cable
length increases, this reduced cycle time can lead to erratic operation.
The total IDE cable length must not exceed 18 inches. If two IDE drives
are connected, they must not be more than six inches apart.

Environmental Specifications

Characteristic
Temperature
Operating
Non-operating
Humidity
Operating
Non-operating
Altitude
Operating
Nonoperating
a
Vibration
(3512, 3515 systems
Operating
Nonoperating
a
Shock
(3512, 3515 systems
Operating
Nonoperating
a
These values are with solid state hard drives and NOT rotating media drives
b
Consistent with system level specifications. See your system manual if you have a system other than
the 3512 or 3515 models.
10
Caution
Table 1-1. Environmental Specifications
0° to 55° C (32° to 140° F)
-40° to 85°C (-40° to 185°F)
20% to 80% RH noncondensing
20% to 80% RH noncondensing
Sea level to 10,000 feet (3048 m)
Sea level to 50,000 feet (15240 m)
b
)
5 to 55Hz
0.006" peak to peak displacement
56-2000 Hz
1.0g maximum acceleration
5-55 Hz
0.006" peak to peak displacement
56-2000 Hz
2.5 g maximum acceleration
b
)
15g peak acceleration, 11 msec duration
30g peak acceleration, 11 msec duration
Specification