Changing The Battery; Using The Gr50 Internal Battery And Charger - Leica SPIDER GR30 User Manual

Hide thumbs Also See for SPIDER GR30:
Table of Contents

Advertisement

Operation / Discharg-
ing
7.2.2
Insert and remove the
battery on the GR50
step-by-step
7.2.3
Charging
Operation
The batteries can be operated from -20°C to +65°C/-4°F to +149°F.
Low operating temperatures reduce the capacity that can be drawn; high
operating temperatures reduce the service life of the battery.

Changing the Battery

011646_001
Step
Description
The battery is inserted in the front of the instrument.
1.
Loosen the screws on the battery compartment with the Allen key
provided with the GR50.
2.
Remove the battery cover.
3.
With the arrow facing forward, slide the battery into the battery com-
partment and push so that it locks into position.
4.
Replace the cover of the battery compartment and tighten the
screws.
5.
To remove the battery, loosen the screws and remove the cover of
the battery compartment.
6.
Push the ledge on the right side of the battery compartment to the
right until it releases the battery.
7.
Pull out the battery.
8.
Replace the cover of the battery compartment and tighten the
screws.

Using the GR50 Internal Battery and Charger

Battery charging can be enabled in the GR50 web interface. Refer to the
"GR/GM Series Operational Manual (Online Help)" for further information.
Note: When charging the GEB242 battery with the GR50 internal charger, it
is technically possible to charge the GEB242 battery between -20°C to
+65°C/-4°F to +149°F. Please note the internal temperature reading on the
GR50 web interface.
When the GR50 is turned on, the battery charging status is indicated in
the GR50 web interface.
When the GR50 is powered down, battery charging is indicated via the
LEDs. For further information refer to "5.1 LED Indicators on GR50".