Intel M70KLP Series Technical Product Specification page 15

Hide thumbs Also See for M70KLP Series:
Table of Contents

Advertisement

Intel® Server System M70KLP Family Technical Product Specification
System Options
Front Control and I/O Panel
Features
Power Supply
System Cooling Features
Management Support
Serviceability Features
Operating Ambient
Temperature Support
Security
Rack Mount Kit
(Included)
13
Standard System - No GPU Support
Left Front Control Panel Features
System Power Button / LED
UID Button / LED
Various system feature/status LEDs
Right Front I/O Panel Features
VGA connector
One (1) USB 3.0 connector
One (1) USB 2.0 connector
Two (2) CRPS AC 2000W (80-Plus Platinum)
power supply modules
Supported operating modes:
1+1 Redundant power (hot swappable)
2+0 Combined Power (No power
redundancy)
• Six (6) managed 60x60x56 mm system
fans with support for fan redundancy
• One Fan per installed power supply
• Four (4) 2U CPU heat sinks
• Standard air duct
• One (1) Dedicated RJ45 1Gb Management Port (Back Panel)
• Standard System Management features
Virtual KVM over HTML5
o
Integrated BMC Web Console
o
Redfish*
o
IPMI 2.0
o
Out-of-band BIOS/BMC Update and Configuration
o
System Inventory
o
Autonomous Debug Log
o
• Advanced System Management features (Optional)
Virtual Media Image Redirection (HTML5 and Java)
o
Virtual Media over network share and local folder
o
Active Directory support
o
• Support for Intel® Data Center Management software (Intel® DCM)
Tool-less (Removal / Installation)
• Top cover
• PCIe add-in cards and OCP 3.0 Add-in card
• System fans – hot swappable
• System fan housing
• Power Distribution Board
• Power Supply Module(s) – hot swappable in 1+1 redundant configuration
• Front Drive Bay Backplane(s)
• Front Mount Drives – Hot Swappable in fault tolerant RAID configurations.
o Screws required to mount drive to drive carrier
• 10 – 35° C ambient temperature
TPM 2.0 Option (Rest of the world) - iPC KLPTPM
Intel® PFR – Intel® Platform Firmware Resilience
Intel® CBnT – Converged Boot Guard and Intel® Trusted Execution (Intel® TXT)
Rack mount rails
Tool-less attachment to chassis and rack installation
Full extension from rack
38 Kg maximum supported weight
System with GPU Support
Two (2) CRPS AC 2000W (80-Plus Platinum)
power supply modules
Supported operating modes:
1+1 Redundant Power (hot swappable)
2+0 Combined Power (No power
redundancy)
• Six (6) managed 60x60x56 mm system fans
with support for fan redundancy
• One Fan per installed power supply
• Four (4) 1U CPU heat sinks
• Low Profile air duct
(Note: China only TPM not available)