Epson S5U13700B00C User Manual page 10

S1d13700 embedded memory graphics lcd controller
Hide thumbs Also See for S5U13700B00C:
Table of Contents

Advertisement

Installation and Configuration
JP1 - HIOVDD
JP1 can be used to measure the current consumption of the S1D13700 host interface.
When the jumper is at position 1-2, normal operation is selected.
When no jumper is installed, host interface current consumption can be measured across
JP1.
Note
The HIOVDD voltage can be selected to be +3.3V or +5V using jumper JP7.
JP1
HIOVDD current
Normal Operation
measurement
Top View
Figure 3-2: Configuration Jumper JP1 Location
10
Seiko Epson Corporation
S5U13700B00C Rev 1.0 Evaluation Board
Rev. 1.1