1-11. Flexible Flat Cable, Flexible Board and Fine-Wire Coaxial Cable

1-11-1. Disconnecting/Connecting Flexible Flat Cable and Flexible Board

Note
Be very careful not to fold flexible flat cables and flexible board. Life of flexible flat cable will be significantly shortened if
them are folded and flexible board.
Each flexible flat cable and flexible board has conductive side and insulated side. If the flexible flat cable and flexible board are
connected in the wrong orientation of the conductive side and the insulated side, the circuit will not function.
Check that the conductive side of the flexible flat cable and flexible board are not contaminated.
Securely insert the flexible flat cable and flexible board into the deep end of the connector.
Type A
Connector
Insulating
surface
Unlock
Flexible flat cable
and flexible board
Type D
Flexible flat cable
and flexible board
Contact
surface
Unlock
Connector
Disconnection
1.
Unlock the connector.
2.
Pull out the flexible flat cable and flexible board.
Connection
1.
Unlock the connector.
2.
Insert the flexible flat cable into the connector.
3.
Lock the connector.
Type B
Connector
Insulating
Unlock
surface
Flexible flat cable
and flexible board
Type C
Connector
Contact
Unlock
surface
Flexible flat cable
and flexible board