Define The Load Case, Calculate The Maximum Torque, Select The Motor - Siemens SIMOTICS T-1FW3 Configuration Manual

Complete torque motors
Table of Contents

Advertisement

5.2.3

Define the load case, calculate the maximum torque, select the motor

The motor-specific limiting curves are used as basis when selecting a motor.
These define the torque characteristic with respect to speed and take into account the motor
limits based on the line supply voltage and the function of the infeed.
SINAMICS ALM 400 V line supply (600 V DC link voltage)
M in Nm; n in rpm
Figure 5-1
The motor is selected on the basis of the load specified by the application. Different
characteristics must be used for different loads.
The following operating scenarios have been defined:
● Load duty cycles with constant on period
● Load duty cycles with varying on period
● Duty cycle, variable
1FW3 complete torque motors
Configuration Manual, 08/2020, A5E46027705B AA
Limiting characteristics for synchronous motors 1FW3201-1☐E☐
Configuration
5.2 Configuring workflow
95