Scope Of Delivery; Preassembled Built-In Torque Motor With Cooling Jacket - Siemens SIMOTICS T-1FW6 Configuration Manual

Built-in torque motors
Hide thumbs Also See for SIMOTICS T-1FW6:
Table of Contents

Advertisement

Ambient parameter
h)
i)
j)
k)
l)
m)
n)
o)
p)
1)
Conditions in mines are not considered.
2)
A cooling system based on natural convection can be disturbed by unforeseen air movements.
3)
4)
The limit value of 78.4 KPa covers altitudes up to 2000 m.
Additional ambient conditions applicable for the motors for stationary use at weather-
protected locations according to standard DIN IEC 60721‑3‑3 include.
Mechanically active ambient conditions
Mechanical ambient conditions
Note
Installation instructions
The motors are not suitable for operation
• In salt-laden or corrosive atmospheres
• Outdoors
You can find additional data on the environmental conditions, such as ambient temperatures
or conditions for transport and storage of the motors, in the relevant chapters of this
documentation.
3.2.6

Scope of delivery

3.2.6.1

Preassembled built-in torque motor with cooling jacket

• Stator with a cooling jacket; one cable for the power connection and one cable for the signal
connection with connector or open core ends
• The rotor is secured in the stator by means of transport locks and is protected using a spacer
film
• Transportation locks with spacers and screws
• O-rings (quantity: 2)
1FW6 Built-in torque motors
Configuration Manual, 09/2022, A5E52220645B AA
Low air pressure
4)
High air pressure
2)
Solar radiation (insolation)
Thermal radiation
Air movement
3)
Condensation
Wind-driven precipitation
(rain, snow, hail, etc.)
Water (other than rain)
Formation of ice
Averaged over a period of 5 min
Description of the motor
3.2 Technical features and ambient conditions
Unit
kPa
kPa
W/m
2
-
m/s
-
-
-
-
Class 3S1
Class 3M3
Value
78.4
106
700
-
1.0
Not permissible
-
See degree of
protection
-
41

Advertisement

Table of Contents
loading