Siemens SIMOTICS T-1FW3 Configuration Manual page 128

Complete torque motors
Table of Contents

Advertisement

Configuration
5.4 Mounting
Mounting the clamping elements of option +Q30
A
1
2
3
Procedure
1. Using the clamping element (possibly with centering sleeve), mount the motor at the
intended position on the shaft extension.
2. Using screws (3) clamp the tapered ring (2) onto the tapered sleeve (1). Initially tighten all
screws diagonally so that they are hand tight (5 to 8 Nm).
3. Then tighten all of the screws (3) diagonally using a torque wrench. When doing this, the
screw may only be tightened through a maximum of ¼ of a turn. Repeat this operation
until all of the the screws are tightened with the specified torque using a torque wrench.
When doing this, comply with the specified torques. Then check that the motor runs true.
4. Then check the gap between the tapered sleeve (1) and tapered ring (2) and between the
tapered sleeve (1) and the forcing-off screws (4). There must be a minimum gap of
there is a risk that the clamping element will not fulfill its function (excessively low joint
interference and therefore inadequate torque transmission).
Causes could be for hollow shaft extension:
The clamping elements have been mounted.
126
Shaft shoulder
Tapered sleeve
Tapered ring
Clamping screw
Shaft height
Torque [Nm]
0.1 mm around the complete circumference. If this minimum gap does not exist, then
- excessively low wall thickness, or
- excessively low diameter of the clamping seat
B
Shaft journal
4
Forcing-off screw
5
Lock nut
150
200
127
127
1FW3 complete torque motors
Configuration Manual, 08/2020, A5E46027705B AA
280
210

Hide quick links:

Advertisement

Table of Contents
loading