5.4 Mounting
5.4.9

Vibration resistance

The following factors influence the system vibrational behavior at the site of installation:
● Output elements
● Mounting situation
● Alignment and installation
● Effects of external vibration
As a consequence, motor vibration values can increase.
It may be necessary that you completely balance the rotor together with the output element.
Observe the specified vibration values at the specified motor measuring points. In this way
you guarantee perfect function and long service life of the motor.
Table 5- 8
Vibration frequency
< 6.3 Hz
6.3 - 250 Hz
> 250 Hz
Table 5- 9
Vibration velocity
v
rms
1)
146
Maximum permissible radial vibration values, based on ISO 10816
Max. permissible axial vibration values
= 4.5 mm/s
Both values must be maintained simultaneously.
Vibration values
Vibration displacement s ≤ 0.16 mm
Vibration velocity v
≤ 4.5 mm/s
rms
Vibration acceleration a ≤ 10 m/s
1)
Vibration acceleration
a
= 2.25 m/s
2
peak