Siemens SIMOTICS T-1FW3 Configuration Manual page 78

Complete torque motors
Table of Contents

Advertisement

Motor components and options
4.1 Motor components
1
2
3
Figure 4-2
Two temperature sensor types are integrated:
Temperature sensors KTY 84 are ESD components. When
delivered, they are short-circuited with a terminal.
Temperature sensors of the same type are always installed in one particular motor.
The type of temperature sensor installed is stamped on the rating plate.
Table 4- 1
Features and technical data
Type
Resistance when cold (20 °C)
Resistance when hot (100 °C)
Connection
Response temperature
The resistance change is proportional to the winding temperature change. The temperature
characteristic is taken into account in the closed-loop control.
76
Reserve with plug-in connection in the insulating tubing
Reserve
Connected temperature sensor
Example: Connection in the terminal box
KTY 84
KTY 84-130
Approx. 580 Ω
Approx. 1000 Ω
Via signal cable
Prewarning < 150 °C
Alarm/trip at max. 170 °C ±5 °C
Pt1000 temperature sensors are not ESD components.
Pt1000
Approx. 1090 Ω
Approx. 1390 Ω
Via signal cable
Prewarning < 150 °C
Alarm/trip at max. 170 °C ±5 °C
Configuration Manual, 08/2020, A5E46027705B AA
Pt1000
1FW3 complete torque motors