Siemens SIMOTICS T-1FW3 Configuration Manual page 36

Complete torque motors
Table of Contents

Advertisement

Description of the motor
2.5 Selection and ordering data
Motor type
Rated current /
1FW3287-2☐E
1FW3287-2☐G
1FW328☐ High Speed
1FW3281-3☐J
1FW3281-3☐M
1FW3281-3☐P
1FW3283-3☐J
1FW3283-3☐M
1FW3283-3☐P
1FW3285-3☐J
1FW3285-3☐M
1FW3285-3☐P **
)
1FW3287-3☐J **
)
1FW3287-3☐M **
)
1FW3287-3☐P **
)
*
Other supply voltages can also be configured in SIZER.
)
**
The rated output current of the motor module includes a derating factor due to the pulse frequency.
)
Note
Sound pressure level when reducing the pulse frequency
When the pulse frequency is reduced, a significantly higher sound pressure level can occur.
34
Order designation (Article No.)
stall current
Motor Module SINAMICS S120
I
[A] / I
[A]
N
0
Line supply voltage of 400 V 3 AC, Active Line Module (V
230 / 234
6SL3320-1TE32-6AA☐
352 / 365
6SL3320-1TE33-8AA☐
188 / 200
6SL3120-1TE32-0AA☐
256 / 291
6SL3320-1TE33-1AA☐
315 / 403
6SL3320-1TE33-8AA☐
275 / 292
6SL3320-1TE33-1AA☐
357 / 402
6SL3320-1TE33-8AA☐
424 / 538
6SL3320-1TE35-0AA☐
376 / 400
6SL3320-1TE33-8AA☐
469 / 532
6SL3320-1TE35-0AA☐
638 / 806
6SL3320-1TE38-4AA☐
504 / 534
6SL3320-1TE37-5AA☐
696 / 787
6SL3320-1TE38-4AA☐
830 / 830
6SL3320-1TE41-0AA☐
Rated current
Rated pulse frequency
Motor Module
I
[A]
N
= 425 V)
*)
mot
260
380
200
310
380
310
380
490
380
490
731
618
731
906
1FW3 complete torque motors
Configuration Manual, 08/2020, A5E46027705B AA
Motor
f
[kHz]
pulseN
2
2
4
2
2
2
2
2
2
2
2
2
2
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents