3Com SuperStack 3C16115 User Manual page 151

Proxy servers
Hide thumbs Also See for SuperStack 3C16115:
Table of Contents

Advertisement

C
Physical Dimensions
Environmental Requirements
Operating Temperature
Storage Temperature
Operating Humidity
Standards
Safety
Agency Certifications
EMC
Emissions
Immunity
Heat Dissipation
Power Supply
AC Line Frequency
Input Voltage Options
Current Rating
(continued)
T
ECHNICAL
Height: 44.45mm (1.75 in.) x Width: 482.6 mm (19.00 in.) x Depth: 610 mm
(24.02 in.) (not including bulge). Weight: 13 Kg (28.66 lbs)
0 ° to 40 °C (32 ° to 104 °F)
–10 ° to +70 °C (14 ° to 158 °F)
10–95% relative humidity, non-condensing
EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32.
Operational testing: paras 2.1, 2.2, 2.30 and 2.13).
UL 1950, EN60950, CSA 22.2 No. 950, IEC 60950, NOM-019 SCFI,
AS/NZS 60950
ICES-003 Class A, FCC Part 15 Class A, EN55022 Class A, VCCI Class A,
AS/NZS 3548 Class A, CISPRR 22 Class A, EN61000-3-2, EN61000-3-3,
CNS 13438 Class A, Korean EMI Class A
EN 55024
400 watts maximum (1300 BTU/hour maximum)
50/60 Hz
90–240 VAC
4 A (amps) (maximum)
S
PECIFICATIONS

Advertisement

Table of Contents
loading